Technical Specifications

Testing & Diagnostics

Testing & Diagnostics

Network loop-backs (structured DS3: DS3 port; unstructured DS3, E3 port)

Service loop-backs (structured DS3: DS3 port, tributary and DS0; unstructured DS3, E3)

Internal BERT generation and monitoring (structured DS3, unstructured DS3, E3)

FEAC loop-back generation and detection

Power

–48 VDC dual inputs, labeled A and B

240 W maximum for fully populated system

10 watts per NIM

8 watts per SAM

20 watts per CPU Fused at 7.5 A, each input Alarm power module, 1 slot

Over-voltage threshold: 58 ± 1.5 VDC

Under-voltage threshold: 38 ± 0.72 VDC Optional Dual Redundant AC Power Supply, external

Regulatory Approvals

FCC Part 15, Class A radiated emissions

ANSI/UL 60950, CSA-C22.2 NO. 60950-00

FIPS-140-2 Validated

Joint Interoperability Test Command (JITC) Certified

DISA Information Assurance (IA) Tested

Network Equipment Building Standard (NEBS) Validated, Level 3

A-4

Broadmore 1750 - Release 4.6

Page 366
Image 366
Carrier Access 1750 user manual Testing & Diagnostics, Regulatory Approvals