Broadmore 1750 - Release 4.6 6-3
Electrical Installation
Electrical Requirements

Electrical Requirements

Tools ... 6-3
Power ... 6-3
Cable Management ... 6-3
Tools
The following tools are recommended to install, configure, operate, and maintain the
Broadmore 1750:
#1 flathead screwdriver (for cover removal/installation)
¼-inch hex driver
Dual jeweler’s flathead/Phillips screwdriver
PC with VT100 Emulation software program
DC Volt-Ohm Meter (VOM)
ESD wrist strap
Other standard electronic installation tools as preferred

Power

DC power connections are made at the rear of the Broadmore chassis. The primary DC
power source is –48 volts at 5 amperes and is connected to the “A” inputs. For
redundancy, a second –48 VDC source may be connected to the “B” inputs.
For AC power applications, the optional dual AC redundant power supply tray is
usually mounted below the Broadmore and requires 110/240 VAC, 50/60 Hz. AC
power is connec ted at the rear of the po wer supply tray, and th e two –48 VDC outputs
are then wired to the DC power inputs on the Broadmore chassis.

Cable Management

Overall cable lengths can be optimized through equipment location. Access and cable
strain-relief tie-down points are provided.