Tri-M Systems HE104 Connector CN5 Pinout Connector CN6 Pinout, PC/104 Bus Interrupts Optional

Page 13

23 June 2005

HE104MAN-V8 Manual

Figure 2.3, HE104 Mezzanine Connectors

Connector CN5 Pinout

Connector CN6 Pinout

1.

+5V

10. +5V

1. PM104-P1

10. Main Pwr. Input

2. Common

9. Common

2. Common

9. Common

3.

+Battery Input

8.

Main Pwr Input

3. PM104-P7

8. PM104-P2

4.

Ext. Signal 1

7.

+12V

4. PM104-P6

7. PM104-P3

5.

Ext. Signal 2

6.

-5V

5. PM104-P5

6. PM104-P4

2.7 PC/104 Bus Interrupts (Optional)

Interrupts to the PC/104 bus require the installation of the optional power management mircrocontroller (PM104). The PM104 can be programmed to provide indication of loss of input power, low battery voltage or to provide indication to the PC/104 CPU to begin an orderly shutdown of program operation.

Two separate interrupt requests can be generated and each interrupt request will remain active until the cause of the interrupt request returns to normal. Interrupt Int1 can be set to IRQ6 or IRQ7, while interrupt Int2 can be set to IRQ4 or IRQ5 by installing an appropriate jumper on jumper selections block J4. Jumper block J4 is located adjacent to the PC/104 bus on the opposite side where the power LEDs are located.

Tri-M Engineering

Tel:

800.665.5600, 604.945.9565

12

1407 Kebet Way, Unit 100

Fax:

604.945.9566

 

Port Coquitlam, BC V3C 6L3

E-mail:

info@tri-m.com

 

Canada

Web site:

www.tri-m.com

 

Image 13
Contents HE104 TRI-MTechnical Manual TRI-M Engineering PC/104 Vehicle Power SupplyHE104MAN-V8 Manual Preface General Description IntroductionHE104 Dimensions 1000mil=1in FeaturesModel HE104 SpecificationsIntroduction Configuration and InstallationHE104 Connectors Power ConsiderationsOutput Power Connector Bus Termination Optional Installation Onto PC104 ModulesJumper Selection 2 +5VDC Low Q/ Noise Q=quiescent PC/104 Bus Interrupts Optional Connector CN5 Pinout Connector CN6 PinoutInterrupt IRQ Selection Power Management Controller PM104 optionalPM104 Pin Number and I/O Functions Low Input Alarm10 HE104 Efficiency and Heat Dissipation Calculation Switching Regulator, +5VDC Input power protectionTheory of Operation Charge Pumps Switching regulator, +12VDCVp -p L1 ∙ frequency Filter CapacitorsRC1 RC2 RC3 RC4 RC5 ExampleAppendix 1 HE104, +5V Regulator Block Diagram HE104MAN-V8 Manual Appendix 2 Advantages of Using AC Termination Appendix 3 Installation Hints for the HE104 Power Supply Description AppendixConnections Programming Cable Sample Battery Charging Program Listing BattChrgTerm ‘Get battery charging voltageInit ‘Return to programBattTrickle ‘debug trickle gosub ChkPwr let D1 = NoPower ‘debug nopwr pauseChkPwr BattChrgDistributed By