23 June 2005
HE104MAN-V8 Manual
Examples of NMH0515S can generate the following voltages:
-15V by connecting NMH “0V” to HE104 common
-
-+30V by connecting NMH
-+42V by connecting NMH
Note: When batteries or external signals are connected to CN3 the
2.4 Bus Termination (Optional)
AC bus termination minimizes power consumption as it improves the reliability of the bus. The resistor/capacitor combination only conducts a current during the few nanoseconds when the bus signal is changing state. See appendix “B”.
2.5 Installation Onto PC104 Modules
The PC/104 bus on the HE104, is keyed according to the standards as set out by the PC/104 Consortium Guidelines. Pin B10, of the
Because of the large number of pins and sockets (104 total) in the PC/104 bus, caution must be used in separating the PC/104 modules to prevent bending of the pins or cutting the person separating the modules.
2.6 Jumper Selection
This section describes the function, the location of it, the default setting and how to change each jumper on the
2.6.1 LED Jumper Enable/Disable
The jumpers that are located behind each LED, allow the LEDs to be disabled, which are most likely to be used when absolute minimum power consumption is maintained such as, when operating off a limited battery source..
Each LED is enabled by factory default. To disable any LED, remove the LED jumper (or cut the small PCB trace if no jumper is installed) associated with the LED. To
| Tel: | 800.665.5600, 604.945.9565 | 10 |
1407 Kebet Way, Unit 100 | Fax: | 604.945.9566 |
|
Port Coquitlam, BC V3C 6L3 |
| ||
Canada | Web site: |
|