Tascam MMR-8 owner manual Setup Menu Chart, Menu # Menu Name Parameters

Page 75

Setup Menu Chart

This chart lists all of the Setup Menus and their parameters. Note that * indicates the default selection.

MENU #

MENU NAME

PARAMETERS

000

Control Mode

Local/MMR*

 

 

Time Code Chase

 

 

Biphase Chase

 

 

Biphase Transport

 

 

Serial Transport

 

 

Editor

 

 

 

Varispeed

001

Frame Reference

Automatic*

 

 

Video

 

002

Sample Reference

Automatic*

 

 

AES/EBU Input

 

 

Ext Wordclock

003

Time Code Type

24/24

 

 

 

25/25

 

 

 

29.97/DF

 

 

29.97/NDF

 

 

30/DF

 

 

 

30/NDF*

004

Sample Rate

42294 (44x23/25)

 

 

42336 (44x24/25)

 

 

44056

(44100-)

 

 

44100

 

 

 

44144

(44100+)

 

 

45938 (44x25/24)

 

 

45983 (44x25/23)

 

 

46034 (48x23/25)

 

 

46080 (48x24/25)

 

 

47952

(48000-)

 

 

48000*

 

 

 

48048

(48000+)

 

 

50000 (48x25/24)

 

 

50050 (48x25/23)

 

 

 

 

100

Sync Group

1*

 

 

 

2

 

 

 

3

 

 

 

4

 

110

MMR Bus Request

Master

Off*

Slave

MMR-8 Tascam MMR-8 Owner’s Manual • Chapter 4 • MMR-8 Setup Menus

69

Image 75
Contents MMR-8 HAZARD, do not Expose this Appliance to Rain or Moisture Teac Corporation Important Safety Instructions Page Page Page Page Page MMR-8 MMR-8 ChapterMMR-8 Operation MMR-8 System Applications 105 MMR-8 Introduction General InformationHardware Overview Page Functional Overview Page State LCD Window Display Comment Normal SetupError BackupSystem Specifications Page MMR-8 Materials Kit Box InstallationMounting Rack Ears General GuidelinesMultiple MMR-8 Rack Installation Installing Multiple MMR UnitsAC Mains and Grounding Earthing Considerations Audio CablesMMR-8 Back Panel MMR-8 Back Panel ConnectionsMonitoring Connections Audio ConnectionsAnalog In/Out Connections Digital In/Out ConnectionsVitc Timecode and Video Reference SignalsVideo In/Out SMPTE/EBU Time Code In/OutAES/EBU Sample Rate Biphase ConnectionsDigital Audio Sample Reference Connections Word ClockMMR Sync Bus Connections Midi ConnectionsExternal Controllers & Bus Connections Lynx Bus / KCU ConnectionParallel Transport Connecting External Scsi MediaSerial Transport Connection Serial Editor ConnectionTascam MM-RC Remote Controllers for the Tascam MMR-8Verifying MMR-8 Installation Powering Up the SystemSoftware Updates Testing Your Installation Factory Default SettingsMMR-8 Tascam MMR-8 User’s Guide MMR-8 Operation MMR-8 Keys & Definitions MMR-8 OperationMMR-8 MMR-8 Front Panel Page LED Indicators Front Panel Indicators, Switches, and DisplaysMachine Status LEDs Normal State Display Liquid Crystal Display LCDView Track State Display Setup State DisplayLoad Track State Display Slip Track State DisplayBackup State Display Error State DisplayVerify State Display Front Panel Key Groups Transport GroupMount Setup and Wheel Group ArrowSubf SHIFT+TRIM SHIFT+UPTC/FEET TrimTrack Group WheelSEL SelectSHIFT+SEL Overwrites existing material on track Clipboard contentsInsert Edit To Clipboard w/offset Input MONDelete Shift + LoadSlip TrackNumeric Keys Keypad GroupSHIFT+2 OffsetSHIFT+1 ReaderCapt CLRMMR-8 MMR-8 MMR-8 Loading and Mounting Drives Basic OperationTRK Loading a Project, Session, or CompositionLoading Individual Tracks Loads into any Selected Track IndexDeleting Tracks from the Disk Recording a New ProjectViewing Tracks Unloading TracksUsing Registers Recalling RegistersCapturing the Current Time Code Trimming Time Code Values Using the Entry RegisterHeadphone Volume Level Local & Studio MonitoringHeadphone Jack Phones Setup State & the Setup Menus MMR-8 Setup MenusSetup Operation Menu # Menu Name Parameters Setup Menu ChartMenu # Menu Name Parameters Menu # Menu Name Parameters Menu # Menu Name Parameters Control Mode Setup Menu DetailsSerial Transport User SettingsHead/Tail Lynx BusTransport Control Track Record Arm/SelectPrev/Next Undo/RedoClear/Paste Non-Destructive Record ModeAuto Cleanup Tape ModeMMR Bus Film Post Production MMR-8 System ApplicationsMMR-8 As Master Biphase Setup MenusPage MMR-8 Film Connections Video Post ProductionMMR Input and Output Level Calibrations System Input Level Calibration Using the Meter LEDsMOC Calibration Procedure Input Converter Board Output Converter Board MIC Calibration ProcedureUsing Removable Media Adding External Drives to the SystemFormatting Disks Tascam MMR-8 System SoftwarePage Arrow Appendix a Control Panel Command SummarySetup and Wheel Group Transport GroupKeypad keys Page SHIFT+SEL EDIT+SELMON+SEL INPUT+SELSeagate Nikon MO Drive BelugaUnknown Sony MO DriveTascam MMR-8 Approved Drives SET NFREMOVEID=4 Appendix C WaveFrame CompatibilityPage Appendix D MMR-8 Cable Information Parallel Tracks and Parallel Transport ConnectorMidi IN/THRU/OUT Connector pinout Lynx Remote Controller Connector pinoutEditor Connector pinout Transport Sony 9-pin Connector pinout Biph Biphase Connectors pinout Analog Input & Output Connectors pinoutsSync MMR-Bus Connector pinout DIO AES/EBU Digital Audio Connector pinoutWord Clock OUT Connector Timecode in ConnectorTimecode OUT Connector Word Clock in ConnectorVitc in Connector Scsi ConnectorPRX Connector 104 Appendix E MMR-8 Glossary KCU Control TrackMidi LCDLED LTCAbbreviations Smpte ScsiTerms BIT REC LED Index112 113 114 115 116 117
Related manuals
Manual 6 pages 34.7 Kb

MMR-8 specifications

The Tascam MMP-16 and MMR-8 are two innovative products designed to meet the specialized needs of audio professionals, offering advanced features and capabilities suitable for various recording and playback applications.

The Tascam MMP-16 is a versatile audio router and mixer that excels in different environments, from live sound to studio recording. One of its primary features is the 16-channel configuration, allowing for significant flexibility in signal routing. The MMP-16 supports multiple audio formats, including analog signals, making it adaptable to a wide range of setups. It boasts high-quality AD/DA conversion, delivering excellent audio fidelity and low latency performance.

Additionally, the MMP-16 is equipped with comprehensive digital processing capabilities, including EQ and dynamics processing on each channel. This makes it ideal for both mixing live performances and preparing recordings for post-production. The unit's user-friendly interface includes an intuitive display and physical controls that streamline operation, making it easy for both novice and experienced engineers to navigate.

On the other hand, the Tascam MMR-8 is a robust multi-track digital audio recorder that offers exceptional reliability for professionals who require high-quality audio capture. This 8-channel recorder shines in its ability to handle various digital audio formats, ensuring compatibility with different workflows. One standout feature of the MMR-8 is its solid-state recording technology, which enhances durability and reduces the risk of data loss, a crucial aspect in high-stakes recording environments.

The MMR-8 also provides comprehensive onboard monitoring options, allowing users to assess audio quality in real time. Its extensive connectivity options include digital and analog inputs and outputs, facilitating seamless integration with other studio equipment and live sound systems. The data management capabilities of the MMR-8 make it easy to organize and retrieve recordings, while its compact design ensures portability without compromising on performance.

Both the MMP-16 and MMR-8 showcase Tascam's commitment to innovation and quality in the audio industry. Their advanced features, coupled with solid build quality and ease of use, make them essential tools for audio professionals seeking reliable solutions for their recording and mixing needs. Whether utilized separately or in conjunction, these devices amplify creativity and enhance the overall audio production experience.