Varec 4000 manual Introduction, Using This Manual

Page 11

4000

Introduction

 

 

1 Introduction

1.1Using This Manual

This manual is designed to assist the user with the installation, configuration, operation, maintenance, and troubleshooting of the Varec Model 4000 Advanced Technology Transmitter (ATT).

1.2Getting Acquainted with the Advanced Technology Transmitter (ATT)

The Varec Model 4000 Advanced Technology Transmitter (ATT), in conjunction with a host, represents a data acquisition and communications system for use in liquid level measurement and/or other measurement applications. Liquid level measurement is provided by the Advanced Technology Transmitter coupled to a Varec Model 2500 or other level gauge, as shown in Figure 1-1.

 

Tank Gauge

 

and

 

Transmitter

 

Power

 

Loop

 

Communcations

 

3-wire

 

RTD

 

8130 RTU

FuelsManager

or

8300 TGI

Software

 

 

Loop Communcations

 

Communications

 

between DCS/PLCs

 

for control capabilities

 

Field

 

Junction Box

 

Star Communcations e.g. Mark/Space

Figure 1-1: Tank Installation with Model 4000 ATT

1

Image 11
Contents Installation Operations Manual Page Copyright Disclaimer of Warranties Safety Precaution Definitions Safety Precautions Tank Gauge Transmitter Introduction Tank Gauge Transmitter Glossary Tank Gauge Transmitter Viii Introduction Using This ManualConstruction ConfigurationOperation Installation Part Number Gauge Adapter Kit Mounting the EquipmentConnecting Input Power WiringATT Wiring Wiring PreparationTerminal Block One TB1 Terminal Block Two TB2 Connecting Host CommunicationTypical EIA485 Wiring ATT EIA485 WiringTypical EIA485 System Wiring Typical Mark/Space Field Wiring ATT Mark/Space WiringInstallation Checkout Connecting the RTDConnecting the Handheld Terminal Wiring CompletionFunction Key Description ConfigurationConfiguration Parameters 1200 Hand Held TerminalTerminal Mode Configuration 1200 Hand Held Terminal Terminal Mode OperationMenu Operation Main Menu Description Main MenuSummary Menu Description Summary MenuConfiguration Menu Description Configuration MenuHost Menu Description Host MenuQuick Setup Host Configuration Imperial Fractional 1900 Quick Setup DefaultsGeneral Configuration Imperial Decimal 1900 Quick Setup Defaults 3 0-20 Meter 1900 Quick Setup Defaults 4 0-30 Meter 1900 Quick Setup Defaults 8 0-30 Meters 1800 Series Transmitter Quick Setup Imperial Fractional 1800 Series Transmitter Quick SetupImperial Decimal 1800 Series Transmitter Quick Setup 7 0-20 Meters 1800 Series Transmitter Quick SetupImperial Modbus Quick Setup Defaults Metric Modbus Quick Setup Defaults Battery Replacement Maintenance and TroubleshootingMaintenance Error Message Description TroubleshootingATT Error Status Conditions Status Condition Description ATT Configuration Error CheckingATT Status Conditions Host Communication Loopback Tests Model 1200 Error MessagesEnvironmental SpecificationsSpecifications and Physical Characteristics Input PowerLevel Measurement Agency Acronym Requirement Safety Agency ApprovalsIntrinsic Safety Explosion ProofMajor System Assemblies and Components Assembly/Component Part NumberCommunications Order CodesOrder Codes CPU Board Theory of OperationHost Communications Interfaces Back-up BatteryStatus Inputs and Outputs Atti Communications PortHost Communication Encoder Battery BackupTemperature Measurement Number Exception Mark/Space Host InterfaceFunction Number Compatibility with Varec Tank Polling Unit Modbus Support over Mark/Space Host InterfaceTheory of Operation Model 4040 Display Unit ATT Family of ProductsDigital Inputs Relay SpecificationsModel 4050 Digital Input/Output Unit Digital OutputsImplementation Modbus ImplementationIntroduction Modbus Implementation Term Definition Functions and Data FormatsInteger Registers ATT Response Integer DataHost Request Character Data Packed Bit Data Coded DataFloating Point Data Floating-Point RegistersFloating-Point Data Two 16-bit Registers FormatOne 32-bit Register Format Exception Response Reason Status BitsStatus Bit Data Exception ResponsesHardware Implementation Data Out of RangeLoopback Test Register Number Type Description Integer Register MapRegister Number Sw Ver0-1 Noise Reject Type Status Bit Register Map Floating Point Register MapModbus Implementation 10.3 4000LJFMO Optional Interfaces10.1 4000TIFMO 10.2 4000GEFMO10.6 4000GMFMO 10.5 4000WBFMOAdv Hi Level GlossaryDband TSU Tank Gauge Transmitter 4000 Your official representative Your offical representative