Modbus Implementation |
|
|
| Tank Gauge Transmitter | |
|
|
|
|
|
|
|
|
|
|
|
|
Register Number |
| Type |
| Description |
|
8 |
| Reserved |
|
|
|
9 |
| Code | A/D Noise Reject: Type |
| |
|
|
| 0 | - 60Hz |
|
10 |
| Scaled | 1 | - 50 Hz |
|
| Crit Low Level Setpoint |
| |||
11 |
| Scaled |
| ||
| Adv Low Level Setpoint |
| |||
12 |
| Scaled |
| ||
13 |
| Scaled | Adv High Level Setpoint |
| |
14 |
| Scaled | Crit High Level Setpoint |
| |
15 |
| Scaled |
| ||
| Level Deadband |
| |||
16 |
| Scaled |
| ||
17 |
| Scaled | Crit Low Temp Setpoint |
| |
18 |
| Scaled | Adv Low Temp Setpoint |
| |
19 |
| Scaled |
| ||
| Adv High Temp Setpoint |
| |||
|
|
|
| ||
|
|
| Crit High Temp Setpoint |
| |
|
|
| Temp Deadband |
| |
|
|
|
|
| |
20 |
| Code | Level Units |
| |
|
|
| 0 | - METERS |
|
|
|
| 1 | - FEET |
|
|
|
| 2 | - |
|
21 |
| Code | Temp Units |
| |
|
|
| 0 | - C |
|
|
|
| 1 | - F |
|
|
|
| 2 | - K |
|
22 |
| Code | Level Type |
| |
|
|
| 1 | - FORWARD |
|
|
|
| 2 | - REVERSE |
|
23 |
| Code | Temp Type |
| |
|
|
| 0 | - NONE |
|
|
|
| 1 | - COPPER RTD |
|
|
|
| 2 | - PLATINUM RTD |
|
24 |
| Scaled | Manual Temperature |
| |
25 |
| Code | Max Integer Value |
| |
26 |
| Code | Damping Value |
| |
27 |
| Scaled |
| ||
| Calibration Level |
| |||
|
|
|
| ||
|
|
|
|
| |
28 |
| Code | Quick Setup Option |
| |
|
|
| 0 | - NONE |
|
|
|
| 1 | - ENG FRAC 1800 |
|
|
|
| 2 | - ENG DEC 1800 |
|
|
|
| 3 | - 0 TO 20 M 1800 |
|
|
|
| 4 | - 0 TO 30M 1800 |
|
|
|
| 5 | - ENG FRAC 1900 |
|
|
|
| 6 | - ENG DEC 1900 |
|
|
|
| 7 | - 0 TO 20 M 1900 |
|
|
|
| 8 | - 0 TO 30M 1900 |
|
|
|
| 9 | - METRIC Modbus |
|
|
|
| 10 - IMPERIAL Modbus |
|
56 | Installation and Operations Manual |