Varec 4000 Status Inputs and Outputs, Atti Communications Port, Host Communications Interfaces

Page 48

Theory of Operation

Tank Gauge Transmitter

 

 

7.3Status Inputs and Outputs

Status inputs and outputs are accomplished via a separate I/O Module. The ATT will communicate with the Module via the ATTI port. The state of the inputs will be mapped into Modbus registers to allow a host computer to read them. Control of status outputs will also be available to a host via Modbus registers. This unit is currently under development.

7.4ATTI Communications Port

The ATTI Communication Port is a HART device compatible port. However, it does not power HART devices and is not designed to be intrinsically safe. It is used to communicate with the 1200 Hand Held Terminal for configuration. In the future it will support digital I/O extensions to the ATT including, 4120 Multi-Element Temperature Transmitter and 4040 Tankside display

7.5Host Communications Interfaces

The ATT supports a plug-in host communication interface module. The following host communication modules are supported in the initial release of the ATT.

EIA485 Modbus

Mark/Space

GPE Loop Communications

TIWAY Communications

L&J Tankway Communications

Varec Mark Space Matrix

GSI Modbus

7.6Level Measurement

The HART Level Encoder utilizes a proprietary incremental count technique for determining liquid level. Two code disks are provided in the encoder with each disk containing a number of slots. Optical sensors for each disk detect disk rotation by sensing the passing of these slots. The primary disk contains 128 slots and is used to calculate the actual liquid level. The secondary or check disk contains only four slots and is used to verify or check the level from the primary disk. The count obtained from these sensors is stored in encoder memory.

7.6.1Back-up Battery

The encoder's back-up battery provides continuous operation during power outages. The battery is non-rechargeable with a continuous operating lifetime of 10 days or more and a shelf life of ten years. To preserve the battery life, automatic battery shut down occurs after 24 hours of continuous power outage. The encoder monitors the voltage of the back-up battery and provides a battery low warning to the host in the event the battery needs replacement or has been turned shutdown due to an extended power outage.

7.6.2Damping

The ATT implements a damping scheme to stabilize the level and temperature in turbulent tanks. The amount of damping is specified by a damping value in the 'DAMPING' parameter under the Config Menu. This parameter can be entered via the Model 1200 using the Alter menu.

A damping value of 0 to 16 can be specified. A damping value of 0 implies no damping. A damping value of 16 implies that level and temperature is averaged over 16 readings.

38

Installation and Operations Manual

Image 48
Contents Installation Operations Manual Page Copyright Disclaimer of Warranties Safety Precaution Definitions Safety Precautions Tank Gauge Transmitter Introduction Tank Gauge Transmitter Glossary Tank Gauge Transmitter Viii Using This Manual IntroductionConfiguration OperationConstruction Installation Mounting the Equipment Part Number Gauge Adapter KitWiring ATT WiringWiring Preparation Connecting Input PowerConnecting Host Communication Terminal Block One TB1 Terminal Block Two TB2ATT EIA485 Wiring Typical EIA485 WiringTypical EIA485 System Wiring ATT Mark/Space Wiring Typical Mark/Space Field WiringConnecting the RTD Connecting the Handheld TerminalWiring Completion Installation CheckoutConfiguration Configuration Parameters1200 Hand Held Terminal Function Key DescriptionTerminal Mode Configuration Terminal Mode Operation 1200 Hand Held TerminalMenu Operation Main Menu Main Menu DescriptionSummary Menu Summary Menu DescriptionConfiguration Menu Configuration Menu DescriptionHost Menu Host Menu DescriptionQuick Setup Imperial Fractional 1900 Quick Setup Defaults General ConfigurationHost Configuration Imperial Decimal 1900 Quick Setup Defaults 3 0-20 Meter 1900 Quick Setup Defaults 4 0-30 Meter 1900 Quick Setup Defaults Imperial Fractional 1800 Series Transmitter Quick Setup Imperial Decimal 1800 Series Transmitter Quick Setup7 0-20 Meters 1800 Series Transmitter Quick Setup 8 0-30 Meters 1800 Series Transmitter Quick SetupImperial Modbus Quick Setup Defaults Metric Modbus Quick Setup Defaults Maintenance and Troubleshooting MaintenanceBattery Replacement Troubleshooting ATT Error Status ConditionsError Message Description ATT Configuration Error Checking ATT Status ConditionsStatus Condition Description Model 1200 Error Messages Host Communication Loopback TestsSpecifications Specifications and Physical CharacteristicsInput Power EnvironmentalLevel Measurement Safety Agency Approvals Intrinsic SafetyExplosion Proof Agency Acronym RequirementAssembly/Component Part Number Major System Assemblies and ComponentsOrder Codes CommunicationsOrder Codes Theory of Operation CPU BoardBack-up Battery Status Inputs and OutputsAtti Communications Port Host Communications InterfacesEncoder Battery Backup Temperature MeasurementHost Communication Mark/Space Host Interface Function NumberNumber Exception Modbus Support over Mark/Space Host Interface Compatibility with Varec Tank Polling UnitTheory of Operation ATT Family of Products Model 4040 Display UnitRelay Specifications Model 4050 Digital Input/Output UnitDigital Outputs Digital InputsModbus Implementation IntroductionImplementation Modbus Implementation Functions and Data Formats Integer RegistersTerm Definition Integer Data Host RequestATT Response Character Data Coded Data Packed Bit DataFloating-Point Registers Floating-Point DataTwo 16-bit Registers Format Floating Point DataOne 32-bit Register Format Status Bits Status Bit DataException Responses Exception Response ReasonData Out of Range Loopback TestHardware Implementation Integer Register Map Register Number Type DescriptionRegister Number Sw Ver0-1 Noise Reject Type Floating Point Register Map Status Bit Register MapModbus Implementation Optional Interfaces 10.1 4000TIFMO10.2 4000GEFMO 10.3 4000LJFMO10.5 4000WBFMO 10.6 4000GMFMOGlossary Adv Hi LevelDband TSU Tank Gauge Transmitter 4000 Your official representative Your offical representative