Unitech PT-500 manual Triggering the Scanner Module, Interface Port

Page 10

2.4 Triggering the Scanner Module

The PT-500 can be used with a built-in integrated laser or CCD scanner module. To use the scanner, just point the scanner window at a barcode and press the trigger that activates the scanner. A short beep from the buzzer and flashing red LED indicator on top of the LCD display indicates when the scanning is successful.

2.5 Interface Port

The PT-500 includes a DSUB-9 pin male connector, located at the base of the terminal, for serial communication with a PC. Infra red LEDs and charging contacts for the optional cradle are located on the bottom right below the DB 9 connector. The pin out assignment is shown as follows:

 

 

9

6

 

 

 

5

1

 

Pin

Signal

Direction

Description

1

 

 

 

 

2

RXD

 

Input

Receive

3

TXD

 

Output

Transmitted

4

 

 

 

 

5

GND

Reference Ground

6

 

 

 

 

7

RTS

 

Output

Ready to send

8

CTS

 

Input

Clear to send

9

 

 

 

 

The following diagram shows the way to connect input/output devices to the PT-500.

9

Image 10
Contents USER’S Guide Page Table of Content Chapter InstallationOverview Application Development Technical SpecificationSoftware System UPC, EAN, CODE39, I 2 of 5, CodbarMain Battery Power On and Off the PT-500Batteries Backup Battery Using the Keypad Turn on and off of the terminal Triggering the Scanner Module Interface PortOptional Charging and Communication Cradle Side Spare CommPower MainOperation Ready Mode Page System Mode RUN MenuMain Menu SET MenuTime Menu Code Menu Beep Menu Comm MenuFnky Menu Define F1 Misc Menu DIR Menu DEL MenuDiag LCD Diag MenuDiag KBD Diag MEM Diag COMInit Menu EasyJob Mode InputDump PurgeFormat OFF /ONCRLF/NONE/CR/LF MMDDYYYYhhmmssIf ON, each record will include a Xlink EXE Application ModeEXE Xlib EXEASM BAT Maininfo COMSetenv BAT LNK BAT