7:DATA SKIP

A scanner will normally stop on any transmission it receives. This means the BC250D will occasionally stop on data signals and unmodulated transmissions. You can automatically skip many of these types of transmissions with data skip turned ON.

8:SQ MODE

The SQ Mode allows you to set at your option, whether the scanner will stop on all active transmissions on a particular frequency or it will only respond to transmissions with a pre-set subaudible tone. This applies to both Conventional Search and Scan modes. The options are as follows:

1.CSQ - The default setting is CSQ (carrier squelch). In this mode the scanner will stop on any transmission on a programmed frequency (Squelch mode does not apply to trunking).

2.TONE SQ - In Tone Squelch mode, if you have set a subaudible tone (CTCSS or DCS) for a frequency, the scanner will only stop on that frequency if the transmission includes the prescribed tone.

3.TONE SEARCH - In this mode, as soon as the scanner stops on any (non-trunked) channel, the scanner will begin to search for any subaudible tone that is being used on a transmitted frequency. The scanner will check each CTCSS tone sequentially and it will find DCS tones instantly.

9:BANK TAG

Allows you to set an alphanumeric text tag for individual banks in the scanner (1-10). (The "0" key represents bank number 10.) For example, you may wish to set the bank one text tag as Law Enforcement, the second bank as Fire, etc.

0:P-25 CARD

When you insert the optional card (BCi25D) and select 1:ENABLE in this mode, you can monitor APCO P-25 digital communications. See page 76 for details.

:BATTERY SAVE

When you set Battery Save to ON in this Menu, Battery Save is active in Scan Hold mode (except Priority Scan mode).

25

Image 29
Contents Page Page Contents Edacs Scat LTR IntroductionFront View Icon Description Icon DisplayBC250D Shortcuts Press Important Notice What is Searching? What is Scanning?What is Trunk Tracking? TerminologyWhat is Apco Project 25 Digital Communications? Feature Highlights Page Scanner.uniden.com Where to Obtain More InformationInformation on the Internet Included with Your Scanner Package Installing the Battery Pack SetupCharging the Battery Pack Low Battery IndicatorFlexible Antenna Connecting the Remote CableBeltclip Listening SafelyTurn the Scanner On Setting the SquelchBasic Operation Understanding the Menu System Menu Description and Numeric Keypad Equivalents You can assign a variety of step sizes to the search range 5TONE Data 4BEEP Alert You can assign a variety of step sizes to the channel 8I-CALLMOTOROLA/EDACS 8ID Scan List LTR Cntrl CH only 9BANK TAG Using Storing Frequencies into Channels in Menu ModeProgramming Press MENU/BACKEditing a Stored Frequency Deleting a Stored FrequencyDuplicate Frequency Alert PressStoring Text Tags Transfer FrequenciesPress HOLD/MAN Assigning a Bank Tag to a Bank Press MENU/BACKAssigning the Beep Alert to a Channel Beep AlertProgramming Tips Page During Scanning Press HOLD/MAN ScanningStoring Frequencies During Scanning Setting the Delay Mode for Frequency RF Attenuation FeatureChannel Lockout Lockout in Hold Mode Press HOLD/MANLockout in Scanning Mode Priority Scan Restoring a Locked-out ChannelRestoring All Locked-out Channels Priority Channel Plus Scan Changing the Priority ChannelSearching Setting a Search RangeData Skip Search Hold FeatureStarting Chain Search Storing Search Frequencies Frequency SkipC004 0000.0000 Auto StoringTone Search mode Squelch SQ Mode001 512.0000 NFM Ctcss 250.3 Bank Additional Menu Options for Searching Service Option Service SearchNWR-SAME Alert Service Search SkipProgramming Fips Code Testing the Alert SirenTo clear a stored Fips code, press 0 and E successively Digital and Trunked Systems Page Selecting or Changing Trunking System Type Programming Receiving Digital and Trunked SystemsFor instructions. is complete Programming Trunking FrequenciesProgramming ID Scan Lists Manually To enter an Edacs ID To enter a Type 2 Talk Group IDTo enter a Type 1 ID Assigning a Text Tag to a Talk Group ID Press MENU/BACK To enter a LTR IDReceiving Trunked Systems ID Scan 867.9875 NFM List ID Scan ModeID Monitor Mode ID Scan Hold FeatureTo directly access a specific channel Trunked SearchSCAN, RSM or Search ID Search Hold and Direct Entry ID Hold ModeID Lockout Restoring Locked-out IDs Review ID LockoutTo unlock a single ID, follow these steps Press MENU/BACK To unlock all locked out IDs in a bank onceReverse Key Setting the Delay Mode for Trunking ModeDeleting a Stored ID Setting Priority in Trunking ModeProgramming Scan Lists During Search Call Motorola/EDACS Moving between Scan List MemoriesYou can enter the instant shortcut Multi-TrackMulti-Track Operational Details Edacs Tracking Edacs ReceptionSearch An Edacs Trunked systemAFS Partial Entry Feature Special Edacs FeaturesPatch Tracking LTR Tracking LTR ReceptionMotorola Tracking Motorola ReceptionFleet Map Programming Selecting Preset Fleet MapProgramming a Hybrid System Programming a Fleet Map50.0 Toggling the Status Bit Control Channel Only ModePage Disconnect Tone Detect Option End Code Apco Project Reception Installing the Apco P-25 CardTurning ON/OFF the Apco P-25 Card Precautions for Installing the BCi25D CardThreshold Adjustment Range Apco P-25 Sound Quality Fine TuningPage Remote Interface PC Control ModeTo connect Scanner to PC To program your scannerScanner.uniden.com PC Control Parameter Clone ModeStart Remote Mode and Change Transfer Speed To connect the Scanner to Scanner MasterClone Dimmer Additional FeaturesEnter Lock Key LockKey Beep Option Reverse ModeScreen Mask Channel Step SelectionFrequency and Channel Tuning with the VFO Control Receiving Mode SelectionCare and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Page Appendix Preset Fleet MapsPreset Map Block Type I Programming Information User Defined Fleet MapsSize Code Restrictions Fleet Map Size CodesNWR-SAME Event Code 100 101 102 BC250D Flow Charts103 104 Uniden America Corporation One Year Limited Warranty

BC250D specifications

The Uniden BC250D is a versatile and powerful handheld scanner that caters enthusiastically to the needs of both amateur radio enthusiasts and professionals alike. With its compact design and extensive feature set, the BC250D stands out in the crowded field of communication devices.

One of its significant features is the 200 channels it can store, making it suitable for various scanning tasks. Users can easily program frequencies across public service and amateur bands, including police, fire, and emergency medical services. The BC250D also supports a full range of frequencies from 24 MHz to 1300 MHz, accommodating diverse communication needs.

The scanner’s advanced trunking capabilities allow users to access trunked radio systems, which are frequently used by public safety agencies and commercial entities. It supports both Motorola and EDACS trunking protocols, making it adaptable to numerous scanning scenarios.

Another key characteristic of the BC250D is its customizable scanning options. Users can set priorities for specific channels, enabling them to focus on the most relevant communications. The scanner also features a "Close Call" technology that detects nearby signals automatically, providing real-time monitoring without pre-programmed frequency setups. This feature is particularly beneficial for catching local transmissions that might not be otherwise listed.

The interface of the BC250D is user-friendly, designed to allow easier navigation through its extensive features. The display is crisp and vibrant, presenting information clearly even in low-light conditions. Additionally, the scanner supports alpha tagging, allowing users to assign names to channels for easier identification.

Powering the Uniden BC250D is an internal rechargeable lithium-ion battery, which ensures longer use without the need for frequent battery changes. Plus, with an included belt clip, it’s easy to carry around, making it perfect for users who are always on the go.

In terms of connectivity, the BC250D's built-in computer interface allows for firmware updates and programming through a PC, enhancing its functionality over time.

Overall, the Uniden BC250D combines advanced scanning technology with user-friendly features, solidifying its position as a reliable scanner for a wide range of applications. Whether for hobbyists or professional users, this scanner delivers performance, flexibility, and ease of use.