Uniden BC250D manual

Page 97

Key Beep - This is another term for the tone you hear as a keypad acknowledgement beep. The default setting is on. If you have turned the Key Beep off, you now have a silent keypad. You will not hear a tone each time you press a key.

NWR S.A.M.E. Weather Alert - In 1994, the National Oceanic and Atmospheric Administration (NOAA) began broadcasting coded signals called FIPS (Federal Information Processing System) codes along with the standard weather broadcasts for stations in your area. These codes identify an emergency and the specific geographic area (such as your county) affected by the emergency. The scanner was developed with SAME (Specific Area Messaging Encoding) technology.

This allows you scanner to receive, interpret, and display the information about the codes so you can determine if the emergency might affect you area.Each FIPS code identifies a specific geographic area (defined by the National Weather Service) so your scanner sounds an alert only when a weather emergency is declared in those locations.

This helps you more efficiently track the weather conditions in and around your area.

PC Control - This term is associated with the ability to program frequencies and other useful information via a computer by means of third party software. You can change the transfer speed on the scanner needed to be compatible with your PC. (See page 81)

Scan List - When you designate a bank to be a trunking bank, your scanner sets up 10 Scan Lists, which are simply list of your favorite IDs. Each list can contain up to 10 IDs, so you can store a total of 100 IDs for each trunk bank. These lists are designed to help you organize the trunking system users into categories.

Screen Mask - Screen Mask reduces the amount of information that appears on the display. Alpha tags that you have set for a channel along with a few function icons will appear only on the display. This mode is particularly useful in public safety vehicles where that are already overloaded with information. Screen Mask does not work in Search mode.

Status Bit - This term refers to Motorola Type II systems. There is a method by which special types of communications utilize unique talk group numbers.

For example, if all emergency calls are set to occur on a specific talk group number then you will not miss the transmission even if you have not programmed all the talk group numbers. With the Status Bit on and you have programmed the unique number, then you don’t have to

93

Image 97
Contents Page Page Contents Edacs Scat LTR IntroductionFront View Icon Description Icon DisplayBC250D Shortcuts Press Important Notice What is Searching? What is Scanning?What is Trunk Tracking? TerminologyWhat is Apco Project 25 Digital Communications? Feature Highlights Page Information on the Internet Where to Obtain More InformationScanner.uniden.com Included with Your Scanner Package Installing the Battery Pack SetupCharging the Battery Pack Low Battery IndicatorFlexible Antenna Connecting the Remote CableBeltclip Listening SafelyBasic Operation Setting the SquelchTurn the Scanner On Understanding the Menu System Menu Description and Numeric Keypad Equivalents You can assign a variety of step sizes to the search range 5TONE Data 4BEEP Alert You can assign a variety of step sizes to the channel 8I-CALLMOTOROLA/EDACS 8ID Scan List LTR Cntrl CH only 9BANK TAG Using Storing Frequencies into Channels in Menu ModeProgramming Press MENU/BACKEditing a Stored Frequency Deleting a Stored FrequencyDuplicate Frequency Alert PressStoring Text Tags Transfer FrequenciesPress HOLD/MAN Assigning a Bank Tag to a Bank Press MENU/BACKProgramming Tips Beep AlertAssigning the Beep Alert to a Channel Page Storing Frequencies During Scanning ScanningDuring Scanning Press HOLD/MAN Setting the Delay Mode for Frequency RF Attenuation FeatureLockout in Scanning Mode Lockout in Hold Mode Press HOLD/MANChannel Lockout Restoring All Locked-out Channels Restoring a Locked-out ChannelPriority Scan Priority Channel Plus Scan Changing the Priority ChannelSearching Setting a Search RangeStarting Chain Search Search Hold FeatureData Skip Storing Search Frequencies Frequency SkipC004 0000.0000 Auto StoringTone Search mode Squelch SQ Mode001 512.0000 NFM Ctcss 250.3 Bank Additional Menu Options for Searching Service Option Service SearchNWR-SAME Alert Service Search SkipProgramming Fips Code Testing the Alert SirenTo clear a stored Fips code, press 0 and E successively Digital and Trunked Systems Page Selecting or Changing Trunking System Type Programming Receiving Digital and Trunked SystemsFor instructions. is complete Programming Trunking FrequenciesProgramming ID Scan Lists Manually To enter a Type 1 ID To enter a Type 2 Talk Group IDTo enter an Edacs ID Assigning a Text Tag to a Talk Group ID Press MENU/BACK To enter a LTR IDReceiving Trunked Systems ID Scan 867.9875 NFM List ID Scan ModeID Monitor Mode ID Scan Hold FeatureTo directly access a specific channel Trunked SearchID Lockout ID Search Hold and Direct Entry ID Hold ModeSCAN, RSM or Search Restoring Locked-out IDs Review ID LockoutTo unlock a single ID, follow these steps Press MENU/BACK To unlock all locked out IDs in a bank onceReverse Key Setting the Delay Mode for Trunking ModeProgramming Scan Lists During Search Setting Priority in Trunking ModeDeleting a Stored ID Call Motorola/EDACS Moving between Scan List MemoriesYou can enter the instant shortcut Multi-TrackMulti-Track Operational Details Edacs Tracking Edacs ReceptionSearch An Edacs Trunked systemAFS Partial Entry Feature Special Edacs FeaturesPatch Tracking LTR Tracking LTR ReceptionMotorola Tracking Motorola ReceptionFleet Map Programming Selecting Preset Fleet MapProgramming a Hybrid System Programming a Fleet Map50.0 Toggling the Status Bit Control Channel Only ModePage Disconnect Tone Detect Option End Code Apco Project Reception Installing the Apco P-25 CardTurning ON/OFF the Apco P-25 Card Precautions for Installing the BCi25D CardThreshold Adjustment Range Apco P-25 Sound Quality Fine TuningPage Remote Interface PC Control ModeTo connect Scanner to PC To program your scannerStart Remote Mode and Change Transfer Speed Clone ModeScanner.uniden.com PC Control Parameter To connect the Scanner to Scanner MasterClone Dimmer Additional FeaturesEnter Lock Key LockKey Beep Option Reverse ModeScreen Mask Channel Step SelectionFrequency and Channel Tuning with the VFO Control Receiving Mode SelectionCare and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Page Appendix Preset Fleet MapsPreset Map Block Type I Programming Information User Defined Fleet MapsSize Code Restrictions Fleet Map Size CodesNWR-SAME Event Code 100 101 102 BC250D Flow Charts103 104 Uniden America Corporation One Year Limited Warranty

BC250D specifications

The Uniden BC250D is a versatile and powerful handheld scanner that caters enthusiastically to the needs of both amateur radio enthusiasts and professionals alike. With its compact design and extensive feature set, the BC250D stands out in the crowded field of communication devices.

One of its significant features is the 200 channels it can store, making it suitable for various scanning tasks. Users can easily program frequencies across public service and amateur bands, including police, fire, and emergency medical services. The BC250D also supports a full range of frequencies from 24 MHz to 1300 MHz, accommodating diverse communication needs.

The scanner’s advanced trunking capabilities allow users to access trunked radio systems, which are frequently used by public safety agencies and commercial entities. It supports both Motorola and EDACS trunking protocols, making it adaptable to numerous scanning scenarios.

Another key characteristic of the BC250D is its customizable scanning options. Users can set priorities for specific channels, enabling them to focus on the most relevant communications. The scanner also features a "Close Call" technology that detects nearby signals automatically, providing real-time monitoring without pre-programmed frequency setups. This feature is particularly beneficial for catching local transmissions that might not be otherwise listed.

The interface of the BC250D is user-friendly, designed to allow easier navigation through its extensive features. The display is crisp and vibrant, presenting information clearly even in low-light conditions. Additionally, the scanner supports alpha tagging, allowing users to assign names to channels for easier identification.

Powering the Uniden BC250D is an internal rechargeable lithium-ion battery, which ensures longer use without the need for frequent battery changes. Plus, with an included belt clip, it’s easy to carry around, making it perfect for users who are always on the go.

In terms of connectivity, the BC250D's built-in computer interface allows for firmware updates and programming through a PC, enhancing its functionality over time.

Overall, the Uniden BC250D combines advanced scanning technology with user-friendly features, solidifying its position as a reliable scanner for a wide range of applications. Whether for hobbyists or professional users, this scanner delivers performance, flexibility, and ease of use.