Uniden BC250D manual Testing the Alert Siren, Programming Fips Code

Page 49

Note: You can also set Alert mode to OFF by pressing RSM without entering the Menu mode.

4.When the unit receives a warning signal, it shows a message with the alert siren defined. (For NWR-SAME EVENT CODE, see the table on page 99.)

5.To deactivate, just press any key or it is automatically canceled and the alert siren stops.

Testing the Alert Siren

To test and recognize the difference between the types of alert sirens, perform the following steps:

1.During WX Hold mode and when the WX ALT is OFF, press and hold the PRI key for 2 seconds until you hear the statement alert siren. SIREN TEST appears on the display and the statement, watch and warning sirens sound alternately.

Note: The samples of each alert siren only last for a few seconds. You may need to listen to each siren several times to be sure you recognize the different sirens. The sirens continue to sound rotating through the samples until you silence the test.

2. To stop the test, press any key.

Make sure you can hear the siren in all areas that you would need to. If not, optional accessories can be purchased to ensure that you are alerted for emergency broadcasts.

See your dealer or local electronics store for accessories.

DO NOT USE EARPHONES TO LISTEN TO THE TEST. DAMAGE TO YOUR HEARING COULD OCCUR.

Programming FIPS Code

The 6-digit Federal Information Processing System (FIPS) codes established by the National Weather Service (NWS) must be programmed in your scanner. These codes specify an emergency and the specific geographic area (such as county) affected by the emergency.

1.Press MENU/BACK.

2.Select 1:SERVICE OPTION / 1:WEATHER / 2:ALERT by rotating the VFO and pressing E.

WEATHER ALERT SELECT CODE No.

FIPS CODE 1

------

3.Select 1:ON by rotating the VFO and pressing E.

4.Select the desired memory number (FIPS CODE 1 ~15) by rotating the VFO and pressing E.

45

Image 49
Contents Page Page Contents Edacs Scat LTR IntroductionFront View Icon Description Icon DisplayBC250D Shortcuts Press Important Notice What is Searching? What is Scanning?What is Trunk Tracking? TerminologyWhat is Apco Project 25 Digital Communications? Feature Highlights Page Information on the Internet Where to Obtain More InformationScanner.uniden.com Included with Your Scanner Package Installing the Battery Pack SetupCharging the Battery Pack Low Battery IndicatorFlexible Antenna Connecting the Remote CableBeltclip Listening SafelyBasic Operation Setting the SquelchTurn the Scanner On Understanding the Menu System Menu Description and Numeric Keypad Equivalents You can assign a variety of step sizes to the search range 5TONE Data 4BEEP Alert You can assign a variety of step sizes to the channel 8I-CALLMOTOROLA/EDACS 8ID Scan List LTR Cntrl CH only 9BANK TAG Using Storing Frequencies into Channels in Menu ModeProgramming Press MENU/BACKEditing a Stored Frequency Deleting a Stored FrequencyDuplicate Frequency Alert PressStoring Text Tags Transfer FrequenciesPress HOLD/MAN Assigning a Bank Tag to a Bank Press MENU/BACKProgramming Tips Beep AlertAssigning the Beep Alert to a Channel Page Storing Frequencies During Scanning ScanningDuring Scanning Press HOLD/MAN Setting the Delay Mode for Frequency RF Attenuation FeatureLockout in Scanning Mode Lockout in Hold Mode Press HOLD/MANChannel Lockout Restoring All Locked-out Channels Restoring a Locked-out ChannelPriority Scan Priority Channel Plus Scan Changing the Priority ChannelSearching Setting a Search RangeStarting Chain Search Search Hold FeatureData Skip Storing Search Frequencies Frequency SkipC004 0000.0000 Auto StoringTone Search mode Squelch SQ Mode001 512.0000 NFM Ctcss 250.3 Bank Additional Menu Options for Searching Service Option Service SearchNWR-SAME Alert Service Search SkipProgramming Fips Code Testing the Alert SirenTo clear a stored Fips code, press 0 and E successively Digital and Trunked Systems Page Selecting or Changing Trunking System Type Programming Receiving Digital and Trunked SystemsFor instructions. is complete Programming Trunking FrequenciesProgramming ID Scan Lists Manually To enter a Type 1 ID To enter a Type 2 Talk Group IDTo enter an Edacs ID Assigning a Text Tag to a Talk Group ID Press MENU/BACK To enter a LTR IDReceiving Trunked Systems ID Scan 867.9875 NFM List ID Scan ModeID Monitor Mode ID Scan Hold FeatureTo directly access a specific channel Trunked SearchID Lockout ID Search Hold and Direct Entry ID Hold ModeSCAN, RSM or Search Restoring Locked-out IDs Review ID LockoutTo unlock a single ID, follow these steps Press MENU/BACK To unlock all locked out IDs in a bank onceReverse Key Setting the Delay Mode for Trunking ModeProgramming Scan Lists During Search Setting Priority in Trunking ModeDeleting a Stored ID Call Motorola/EDACS Moving between Scan List MemoriesYou can enter the instant shortcut Multi-TrackMulti-Track Operational Details Edacs Tracking Edacs ReceptionSearch An Edacs Trunked systemAFS Partial Entry Feature Special Edacs FeaturesPatch Tracking LTR Tracking LTR ReceptionMotorola Tracking Motorola ReceptionFleet Map Programming Selecting Preset Fleet MapProgramming a Hybrid System Programming a Fleet Map50.0 Toggling the Status Bit Control Channel Only ModePage Disconnect Tone Detect Option End Code Apco Project Reception Installing the Apco P-25 CardTurning ON/OFF the Apco P-25 Card Precautions for Installing the BCi25D CardThreshold Adjustment Range Apco P-25 Sound Quality Fine TuningPage Remote Interface PC Control ModeTo connect Scanner to PC To program your scannerStart Remote Mode and Change Transfer Speed Clone ModeScanner.uniden.com PC Control Parameter To connect the Scanner to Scanner MasterClone Dimmer Additional FeaturesEnter Lock Key LockKey Beep Option Reverse ModeScreen Mask Channel Step SelectionFrequency and Channel Tuning with the VFO Control Receiving Mode SelectionCare and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Page Appendix Preset Fleet MapsPreset Map Block Type I Programming Information User Defined Fleet MapsSize Code Restrictions Fleet Map Size CodesNWR-SAME Event Code 100 101 102 BC250D Flow Charts103 104 Uniden America Corporation One Year Limited Warranty

BC250D specifications

The Uniden BC250D is a versatile and powerful handheld scanner that caters enthusiastically to the needs of both amateur radio enthusiasts and professionals alike. With its compact design and extensive feature set, the BC250D stands out in the crowded field of communication devices.

One of its significant features is the 200 channels it can store, making it suitable for various scanning tasks. Users can easily program frequencies across public service and amateur bands, including police, fire, and emergency medical services. The BC250D also supports a full range of frequencies from 24 MHz to 1300 MHz, accommodating diverse communication needs.

The scanner’s advanced trunking capabilities allow users to access trunked radio systems, which are frequently used by public safety agencies and commercial entities. It supports both Motorola and EDACS trunking protocols, making it adaptable to numerous scanning scenarios.

Another key characteristic of the BC250D is its customizable scanning options. Users can set priorities for specific channels, enabling them to focus on the most relevant communications. The scanner also features a "Close Call" technology that detects nearby signals automatically, providing real-time monitoring without pre-programmed frequency setups. This feature is particularly beneficial for catching local transmissions that might not be otherwise listed.

The interface of the BC250D is user-friendly, designed to allow easier navigation through its extensive features. The display is crisp and vibrant, presenting information clearly even in low-light conditions. Additionally, the scanner supports alpha tagging, allowing users to assign names to channels for easier identification.

Powering the Uniden BC250D is an internal rechargeable lithium-ion battery, which ensures longer use without the need for frequent battery changes. Plus, with an included belt clip, it’s easy to carry around, making it perfect for users who are always on the go.

In terms of connectivity, the BC250D's built-in computer interface allows for firmware updates and programming through a PC, enhancing its functionality over time.

Overall, the Uniden BC250D combines advanced scanning technology with user-friendly features, solidifying its position as a reliable scanner for a wide range of applications. Whether for hobbyists or professional users, this scanner delivers performance, flexibility, and ease of use.