Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual
6-16 Testing ASMi-52 ASMi-52 Ver. 2.5
ASMI 52
Port log file
Source Name Severity Status Time
1. Local MNGMNT IS DOWN MAJOR ON 0:00:00
2. Local E1 SYNC LOSS LINE A MAJOR ON 0:00:00
3. Local E1 SIGNAL LOSS MAJOR ON 0:00:00
4. Local SYNC LOSS LINE A MAJOR ON 0:00:00
5. Local E1 SYNC LOSS MAJOR OFF 0:11:48
6. Local E1 SIGNAL LOSS MAJOR OFF 0:11:48
7. Local SYNC LOSS LINE A MAJOR OFF 0:23:22
8. Local MNGMNT IS DOWN MAJOR OFF 0:24:25
9. Remote LAN NOT CONNECTED MAJOR ON 0:24:29
ESC-prev. menu; !-main menu; &-exit; @-scroll; ?-help
1 user(s)
Figure 6-15. Port Log File Screen
To clear the log file:
1. From the Physical Port Status menu, select Port Clear Log File (Main menu >
Monitoring > Physical Port Status > Port Clear Log File) to clear the log file.
A confirmation message is displayed at the bottom of the screen.
2. Type Y and press <Enter>.
All the log file entries are deleted from the log file.
6.5 Testing ASMi-52
The user-controlled test functions of ASMi-52 consist of the loopback tests and
LEDs test. The purpose of these tests is to determine the source of a break in the
data flow.
Both local and remote AS Mi-52 units must be configured and synchronized
properly to allow remote loopback activation.
Only one loopback can be activated at a time, either on the local or remote
unit.
Note