Chapter 2

Installation and Setup

2.1 Introduction

This chapter describes installation and setup procedures for the standalone ASMi-52 modem.

After installing the unit:

Refer to Chapter 3 for the operating instructions.

Refer to Chapter 4 for the detailed system configuration procedures using an ASCII terminal connected to the ASMi-52 control port.

If a problem is encountered, refer to Chapter 5 for test and diagnostic instructions.

Internal settings, adjustment, maintenance, and repairs may be performed only by a skilled technician who is aware of the hazards involved.

Always observe standard safety precautions during installation, operation, and Warning maintenance of this product.

The ASMi-52 standalone unit is designed for desktop or bench installation and is delivered as a fully assembled unit. No provisions are made for bolting the unit to a tabletop.

To install ASMi-52:

1.Determine the required configuration of ASMi-52, in accordance with your application.

2.Connect the line (see Connecting the Line below).

3.Connect the DTE (see Connecting the DTE Interface below).

4.Connect power to the unit (see Connecting the Power below).

2.2 Site Requirements and Prerequisites

AC-powered ASMi-52 units should be installed within 1.5m (5 ft) of an easily-accessible grounded AC outlet capable of furnishing the voltage in accordance with ASMi-52 nominal supply voltage.

DC-powered ASMi-52 units require a -48 VDC power source, which must be adequately isolated from the main supply.

ASMi-52 Ver. 2.5

Site Requirements and Prerequisites

2-1

Page 33
Image 33
RAD Data comm manual Introduction, Site Requirements and Prerequisites, To install ASMi-52