Chapter 4 Configuration

Installation and Operation Manual

 

 

2.If the autonegotiation is enabled, choose Max AutoNeg Capability from the Local LAN Configuration menu.

The Set Capability menu appears.

3.Select the required LAN operation mode by choosing one of the following: 10BaseT half duplex

10BaseT full duplex 100BaseT half duplex 100BaseT full duplex.

4.If the autonegotiation is disabled, choose Default Type from the LAN Configuration menu.

The Set Default menu appears.

5.Select the desired LAN operation mode by choosing one of the following: 10BaseT half duplex

10BaseT full duplex 100BaseT half duplex 100BaseT full duplex.

6.From the Local LAN Configuration menu, select Save.

Configuring Fault Indication

If ASMi-52 fault indication is enabled and a faulty condition or a loss of signal is detected on the line, the Ethernet link is disconnected by ASMi-52. If fault indication is not selected, fault conditions are not passed through to the LAN side.

To set the fault indication:

1.From the Local LAN Configuration menu, select Fault Indication (Main menu > Configuration > LAN Configuration > Local LAN Configuration > Fault Indication).

Toggle between Yes and No.

2.Select Save to save your changes.

4.2Configuring ASMi-52 System Parameters

This section describes the procedures for configuring system parameters of

ASMi-52.

To access the Configuration menu:

From the Main menu, select Configuration.

The Configuration menu appears (see Figure 4-16).

4-12

Configuring ASMi-52 System Parameters

ASMi-52 Ver. 2.5

Page 62
Image 62
RAD Data comm manual Configuring ASMi-52 System Parameters, Configuring Fault Indication, To set the fault indication