Installation and Operation Manual

Chapter 1 Introduction

 

 

Receive, recovered from the received line signal (CPE mode).

Management

ASMi-52 supports the following management options:

ASCII terminal or Easy Config hand-held device via V.24/RS-232 terminal port

Telnet via a dedicated 10/100BaseT port

SNMP network management (RADview) via a dedicated 10/100BaseT port

PC, running a Web browsing application (ConfiguRAD)

Inband management via a dedicated timeslot (units with E1/T1 interface only).

EOC

ASMi-52 provides an inband management channel (EOC) for end-to-end system management and supervision. This management channel uses SHDSL overhead bits and operates without interfering with data transmission.

ConfiguRAD

ConfiguRAD is a user-friendly Web-based terminal management system used for remote device configuration and maintenance. It is embedded in ASMi-52 and provided at no extra cost. ConfiguRAD can be run from any standard Web browser.

Dial-In

The V.24 terminal port supports a dial-up modem connection for remote management of ASMi-52 over telephone lines.

Dial-Out

The V.24 terminal port supports alarm dial-out.

Diagnostics

ASMi-52 supports activation of the following:

Local loopback

Remote loopback

Remote loopback at the SHDSL repeater (activated from the local unit)

Internal Bert (multiplexer units only) vs. multiplexer.

All tests can be activated from the local unit or from the remote unit.

ASMi-52 includes an internal Bit Error Rate Tester (BERT) for complete testing of the local and remote modem and the link quality without any need for an external test equipment. ASMi-52 runs an internal pseudo-random 511-bit test pattern in accordance with the ITU V.52 standard.

Real time alarms provide information on the system status, indicating management failure, synchronization loss and other conditions.

ASMi-52 Ver. 2.5

Overview

1-9

Page 25
Image 25
RAD Data comm ASMi-52 manual Management, Diagnostics