ASMi-52 Ver. 2.5 Configuring ASMi-52 for Management 4-1
Chapter 4 Configuration

4.1 Configuring ASMi-52 for Management

The configuration of ASMi-52 is performed via a menu-driven embedded
software, using a standard ASCII terminal or a PC running a terminal emulation
application connected to the rear panel CONTROL port. Alternatively, ASMi-52
can be managed from a Telnet host connected to the 10/100BaseT port on the
rear panel.

Configuring Management Parameters

You must define the ASMi-52 internal SNMP agent parameters in order to enable
SNMP and Telnet management (see Figure 4-1). You can also enter additional
information about your ASMi-52, such as the name of the contact person detail,
unit location, etc.
To access the Management menu:
From the System Configuration menu, select Management (Main menu >
Configuration > System Configuration > Management).
The Management menu appears (Figure 4-1).
ASMi-52
Management
1. Device Info >
2. Host IP >
3. Manager List >
4. Management Access >
5. DTS Configuration >
6. VLAN Encapsulation >
7. MTU (64 - 1540) ... (2240)
8. Save
>
ESC-prev.menu; !-main menu; &-exit; @-scroll
Figure 4-1. Management Menu
DTS Configuration is available only for the units with the E1/T1 DTE interfaces.
MTU means Maximum Transfer Unit.
Notes