Appendix B IR-IP Interface Module

Installation and Operation Manual

 

 

Erasing Configuration

Selecting Erase Configuration allows you to reset all the configuration parameters to their default values.

Note Do this only if you need to reconfigure the module anew (all the parameters).

After erase confirmation all connections with the IR-IP module will be lost. For instructions on further configuration, refer to Performing Preliminary Configuration on page B-6.

Resetting IR-IP

The Reset menu allows you to perform reset of IR-IP, or its interfaces.

This operation can be used to restore normal operation after service is disrupted by an abnormal condition. Any data stored in the IR-IP buffers is discarded, and the flow of traffic is temporarily interrupted.

IR_IP<IR-IP>S/W Ver. 1.21 (date)

Quick Setup Management Access Advanced Setup Device Control

.....................................................................

New Software Download View error LOG Resets

=====================================================================

1.Reset Device

2.Reset LAN

3.Reset WAN

Press one of the numbers to select or ESC:

Figure B-17. Resets Menu

To restart IR-IP:

From the Device Control menu, select Resets. From the Resets menu, type 1. You will be prompted to confirm the reset operation.

Note Resetting the device will restart the IR-IP interface module, and therefore traffic flow is temporarily interrupted, and the Telnet connection is lost.

Reset LAN

To reset the LAN interface:

From the Resets menu, select Reset LAN.

You will be prompted to confirm the reset operation.

B-22

Using the Device Control Menu

ASMi-52 Ver. 2.5