Installation and Operation Manual

Chapter 6 Troubleshooting and Diagnostics

 

 

To run the local loopback:

 

1.

From the Main menu, select Diagnostics.

 

The Diagnostics menu is displayed (see Figure 6-22).

2.

From the Diagnostics menu, select:

 

 

Local Test to run the LLB on the local ASMi-52

 

Remote Test to run the LLB on the remote ASMi-52.

 

The Local/Remote Test menu appears (see Figure 6-23).

3.

Select LLB.

 

The LLB value in parenthesis changes to ON. Also, an additional parameter, Loop Timeout, is displayed for the local ASMi-52.

4.Select Loop Timeout, if you want to set loopback timeout (in minutes). The Loop Timeout value changes.

Note Avoid setting timeout to 0 as local control is lost during LLB. 0=Forever

5. Once you selected the loopback timeout, select Save to activate the LLB.

The LLB is initiated. The TST indicator lights up and the ASMi-52 units lose synchronization.

Diagnostics

ASMi-52

 

5.

Local Test

>

6.

Remote Test

>

7.

Repeater Test

>

>

ESC-previous menu ; !–main menu ; &–exit terminal

 

 

Figure 6-22. Diagnostics Menu

 

 

 

 

 

 

 

 

 

 

 

 

ASMi-52

 

 

 

Local Test or Remote Test

 

 

 

LLB from DTE: OFF

 

 

 

RLB from DTE: OFF

 

 

1.

Bert

>

 

2.

LLB (ON)

 

 

3.

Loop Timeout (min)(0-4095)

...(5)

 

4.

LEDs test

 

 

5.

Clear all

 

 

6.

Save

 

 

>

ESC-previous menu ; !–main menu ; &–exit; @-scroll

Figure 6-23. Local/Remote Test Menu

ASMi-52 Ver. 2.5

Testing ASMi-52

6-21

Page 125
Image 125
RAD Data comm ASMi-52 manual To run the local loopback, Diagnostics Menu