Appendix A Interface Connector SpecificationsInstallation and Operation Manual

 

 

 

 

 

 

Table A-1.

V.35, X.21 and RS-530 Connector Pinouts (Cont.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal

 

 

 

V.35

 

 

RS-530

 

 

 

 

X.21

 

 

Description

 

 

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34-Pin

 

 

 

DB-25

 

 

 

DB-15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin

 

 

Circuit

 

Pin

 

 

Circuit

 

Pin

 

 

Circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Function)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data Set

 

E

 

 

DSR 107

 

6

 

 

CC(A)

 

 

 

 

 

 

 

A positive level from ASMi-52

 

 

Ready

 

 

 

 

 

 

22

 

 

CC(B)

 

 

 

 

 

 

 

when power is on, and ASMi-52

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is (a) not in DIGITAL LOOP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mode, or (b) has not received a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REMOTE LOOPBACK signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

from the remote unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data

 

H

 

DTR 108

 

20

 

 

CD(A)

 

 

 

 

 

 

 

Not used

 

 

Terminal

 

 

 

 

 

 

23

 

 

CD(B)

 

 

 

 

 

 

 

 

 

 

Ready

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Carrier

 

F

 

DCD 109

 

8

 

 

CF(A)

 

5

 

 

I(A)

 

 

A positive level from ASMi-52,

 

 

Detect

 

 

 

 

 

 

10

 

 

CF(B)

 

12

 

 

I(B)

 

 

except when a loss of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

received signal is detected or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Indication)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

when Data Set Ready is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

negative.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External

 

U

 

 

SCTE(A) 113

 

24

 

 

DA(A)

 

7

 

 

(A)

 

 

A serial data rate clock input

 

 

Transmit

 

W

 

 

SCTE(B) 113

 

11

 

 

DA(B)

 

14

 

 

(B)

 

 

from the data source. Positive

 

 

Clock

 

 

 

 

 

 

 

 

 

 

 

clock translations must

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

correspond to data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

transmissions.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transmit

 

Y

 

 

SCT(A) 114

 

15

 

 

DB(A)

 

6

 

 

S(A)

 

 

A transmit data rate clock for

 

 

Clock

 

a

 

 

SCT(B) 114

 

12

 

 

DB(B)

 

13

 

 

S(B)

 

 

use by an external data source.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Positive clock translations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

correspond to data translations.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timing)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Receive

 

V

 

 

SCR(A)

 

17

 

 

DD(A)

 

 

 

 

 

 

 

A receive data rate clock output

 

 

Clock

 

X

 

115

 

9

 

 

DD(B)

 

 

 

 

 

 

 

used by an external data sink.

 

 

 

 

 

 

SCR(B)

 

 

 

 

 

 

 

 

 

 

 

Positive clock translations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115

 

 

 

 

 

 

 

 

 

 

 

 

correspond to data translations.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Local Analog

 

L and j

 

 

 

 

18

 

 

LL

 

 

 

 

 

 

A control signal input, which,

 

 

Loop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

when on, sets ASMi-52 into

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Local Analog Loopback (V.54

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loop 3).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote

 

N and h

 

 

 

 

21

 

 

RL

 

 

 

 

 

 

 

A control signal input which,

 

 

Digital Loop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

when on, commands

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ASMi-52 to send a remote

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loopback command (V.54 Loop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2) to the remote ASMi-52.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test

 

n and k

 

 

 

 

25

 

 

TM

 

 

 

 

 

 

A Control Signal output from

 

 

Indicator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ASMi-52; positive during any

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

test mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A-2

DTE Interface Connectors

ASMi-52 Ver. 2.5

Page 132
Image 132
RAD Data comm ASMi-52 manual 35, X.21 and RS-530 Connector Pinouts, Description Function 34-Pin DB-25 DB-15 Circuit