Chapter 4 Configuration

Installation and Operation Manual

 

 

Configuring the Master Clock

ASMi-52 modems support receive, external and internal clock modes.

When configured to the internal or external clock, ASMi-52 modem operates as an STU-C unit. When configured to the receive clock, ASMi-52 operates as an STU-R unit.

To configure the master clock:

1.From the Master Clock menu (Main menu > Configuration > System Configuration > Master Clock), select the appropriate clock by choosing Receive, Internal, External E1 or External IR (see Figure 4-18).

The System Configuration menu returns.

2.From the System Configuration menu, select Save to save the changes.

ASMi-52

Master clock (Internal)

1.Receive

2.Internal

3.External E1

4.External IR

>

ESC-prev. menu; !-main menu; &-exit; @-scroll

Figure 4-18. Master Clock Menu

Configuring Local Card Mode

Each multiplexer unit may be configured as a single parameter by the local/remote card mode. For example, E1 + IR (Serial DTE) Interface may be configured as E1 or as IR (Serial DTE). The multiplexer can be configured as single but it will not have the characteristics of a multiplexer unit.

For available options and combinations of parameters that complies with multiplexer conditions, see Table 1-4.

To configure local card mode:

1.From the Local menu (Main menu > Configuration > System Configuration > Local Card Mode), select the appropriate configuration by choosing E1, DTE, E1 + LAN, E1 + V35, or V35 + LAN (see Figure 4-19).

The System Configuration menu returns.

2.From the System Configuration menu, select Save to save the changes

4-14

Configuring ASMi-52 System Parameters

ASMi-52 Ver. 2.5

Page 64