Installation and Operation Manual

Chapter 4 Configuration

 

 

Transmit signal mask (DSU mode) – length of a cable in feet between the ASMi-52 T1 port connector and the network access point:

0 feet – 0 to 133 feet

133 feet – 133 to 266 feet

266 feet - 266 to 399 feet

399 feet – 399 to 533 feet

533 feet – 533 to 655 feet

Transmit signal mask (CSU mode) – relative T1 output transmit level:

 

7.5 dB – attenuation of 7.5 dB relative to the nominal transmit level

 

15 dB – attenuation of 15 dB relative to the nominal transmit level

 

22.5 dB – attenuation of 22.5 dB relative to the nominal transmit level

 

Fbit configuration – Fbit transmission mode:

 

Transparent – F bits are sampled at TSER

 

Internally Source – F bits are sourced internally.

Note

 

Configuration of the sync mode, idle mode, timeslot assignment and matching of T1

 

setting of the local and remote units (Unit Identical Set) is identical of that of the E1

 

interface. Refer to Configuring the E1 Interface section above.

 

To access the T1 Configuration menu:

1.From the Configuration menu, select T1 Configuration. The T1 Configuration menu appears.

2.From the T1 Configuration menu, select T1 local port for the local port configuration or select T1 remote port for the remote port configuration.

The T1 Local/Remote Configuration menu appears (see Figure 4-37).

T1

Local Port Configuration

ASMi-52

>(SF)

1.

Framed Mode

2.

Line code

(B8ZS/AMI)

3.

Receive Gain

(LONG/SHORT)

4.

Interface

>(DSU/CSU)

5.

Transmit Signal Mask

(7.5 dB)

6.

Fbit Configuration

(Transparent/Internally Source)

7.

Sync Mode

(FAST)

8.

Units identical setting

(Yes/No)

9.

Idle code

(ff)

10.Time slots assign

>

11.Save

 

>

ESC-prev. menu; !-main menu; &-exit;

Figure 4-37. T1 Port Configuration

ASMi-52 Ver. 2.5

Configuring the Physical Ports

4-35

Page 85
Image 85
RAD Data comm ASMi-52 manual To access the T1 Configuration menu, 37. T1 Port Configuration