Installation and Operation Manual

Chapter 6 Troubleshooting and Diagnostics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ASMi-52

 

 

 

 

Physical port status

 

 

 

 

Port Number

(1)

 

 

1.

Port status

 

 

 

2.

Line mask

(NO_MASK)

 

 

3.Port log file

4.Port clear log file

>

ESC-prev. menu; !-main menu; &-exit; @-scroll

Figure 6-14. Physical Port Status Menu

Masking Port Alarms

ASMi-52 allows you to mask alarms generated by local and remote devices.

To mask ASMi-52 alarms:

From the Physical Port Status menu (Figure 6-14), select Line mask (Main menu > Monitoring > Physical Port Status > Line Mask).

The Line Mask value changes to Mask. ASMi-52 starts ignoring all alarms generated devices connected to the modem.

Table 6-3. ASMi-52 Alarms and Warnings

Number

Terminal Message

Port

Description

Severity

 

 

 

 

 

1

SELF TEST ERROR

Failure occurred during self-test

Major

 

 

 

 

 

2

SOFTWARE

Software download is in progress

Warning

 

DOWNLOAD

 

 

 

 

 

 

 

 

4

LLB FROM DTE

DTE

Local loopback has been activated by a physical

Warning

 

 

 

connector (units with V.35 DTE interface only)

 

 

 

 

 

 

5

RLB FROM DTE

DTE

Remote loopback has been activated by a

Warning

 

 

 

physical connector (units with V.35 DTE interface

 

 

 

 

only)

 

 

 

 

 

 

6

PROP PROT FAIL

SHDSL

FE Management by EOC failed

Warning

 

 

 

 

 

8

LAN NOT

DTE

The Ethernet interface is not connected to the

Major

 

CONNECTED

 

LAN

 

 

 

 

 

 

9

LOOP ATTN. OVER

SHDSL

Line A loop attenuation has exceeded the alarm

Minor

 

LINE A

 

threshold

 

 

 

 

 

 

10

LOOP ATTN. OVER

SHDSL

Line B loop attenuation has exceeded the alarm

Minor

 

LINE B

 

threshold (4-wire units only)

 

 

 

 

 

 

11

SNR MARGIN OVER

SHDSL

Line A signal-to-noise margin has exceeded the

Minor

 

LINE A

 

alarm threshold

 

 

 

 

 

 

ASMi-52 Ver. 2.5

Handling Alarms

6-11

Page 115
Image 115
RAD Data comm manual Masking Port Alarms, To mask ASMi-52 alarms, ASMi-52 Alarms and Warnings