Chapter 6 Troubleshooting and Diagnostics

Installation and Operation Manual

 

 

ASMi-52

E1/T1 current day performance

LocalRemote

Port number (1)

No statistics collection

ESC-prev. menu; !-main menu; &-exit; @-scroll

Figure 6-9. E1/T1 Current Day Performances Screen

Table 6-2. E1/T1 Statistics Parameters

Display

Description

Range

 

 

15 min

24 hour

 

 

 

 

 

 

CRC errors

Number of CRC error events recorded since the last time the register was

 

cleared.

 

 

 

 

 

 

CRC avrg

The average number of CRC events per second. This value is updated

errors

every second.

 

 

 

 

 

 

Current ES

Number of errored seconds in which one or more CRC (Cyclic

0–900

0–65535

 

Redundancy Check) error events occurred during the current interval. This

 

 

 

value is updated every second for 15-minute interval or every 15 minute

 

 

 

for 24-hour interval.

 

 

 

 

 

 

Current SES

Number of severely errored seconds in which 832 or more CRC error

0–900

0–65535

 

events occurred during the current interval. This value is updated every

 

 

 

second for 15-minute interval or every a 15 min. for a 24-hour interval.

 

 

 

 

 

 

Current UAS

Number of unavailable seconds in which a failed signal occurred during

0–900

0–65535

 

the current interval. This value is updated every second for a 15-minute

 

 

 

interval or every a 15 min. for 24-hour intervals.

 

 

 

 

 

 

Current BES

Number bursty errored seconds, in which 2 to 831 CRC error events

0–900

0–65535

 

occurred during the current interval. This value is updated every second.

 

 

 

 

 

 

Current LOFC

Number of loss of frame alignment events measured during the current

0–255

0–255

 

interval. This value is updated every second for 15-minute interval or every

 

 

 

15 min. for 24-hour interval.

 

 

 

 

 

 

Current CSS

Number of seconds with one or more controlled slip events measured

0–255

0–255

 

during the current interval. This value is updated every second for a

 

 

 

15-minute interval or every 15 min. for a 24-hour interval.

 

 

 

 

 

 

24 hour

Total number of degraded minutes in the current 24-hour interval. A

0–1440

degrade

degraded minute is a minute in which the BER exceeded 110-6. This

 

 

minute

value is updated every minute.

 

 

 

 

 

 

24 hour last

Total number of degraded minutes in the last 24-hour interval. This value

0–1440

degrade

is updated every 24 hours.

 

 

minute

 

 

 

 

 

 

 