Chapter 5

Configuring a Typical

Application

5.1 Overview

This chapter provides detailed instructions for setting up two ASMi-52 modems in a typical application.

ASMi-52 configuration is performed via a menu-driven embedded software using a standard ASCII terminal or a PC running a terminal emulation application connected to the rear panel CONTROL port. Alternatively, ASMi-52 can be managed from a Telnet host connected to the 10/100BaseT port on the rear panel. Read Chapter 4 to familiarize yourself with how to operate a terminal.

Application

Two ASMi-52 modems operating opposite each other, one in the central office, the second in the customer premises equipment. User traffic is E1 unframed.

ASCII

Terminal

E1

CO

Unframed

 

CPE

E1

 

Unframed

Router

ASMi-52

ASMi-52

Router

Internal Clock

Receive Clock

 

123.456.78.90

123.456.78.91

 

Figure 5-1. Typical ASMi-52 Application

Guidelines for Configuring ASMi-52 Units

Each ASMi-52 unit must be configured individually. This typical application has the following configuration steps:

1.Setting the system: Setting the clock mode and the device Host IP address

2.Setting the line interface: Setting the Wire mode (2W or 4W)

3.Setting the E1 port: Setting the framing mode.

ASMi-52 Ver. 2.5

Overview