Worth Data 802 RF user manual Automatic Check Back, Code 3 of 9 Code, Key Current Value

Page 18

The prompt for Headphone Volume is:

HEADPHONE VOLUME

Enter 0-9 for Volume

Control

Current Value is: 5

Automatic Check Back

Other

This parameter should not be changed under normal circumstances. After the host sends a prompt, the Terminal goes to sleep waiting on the operator to key or scan input in response to the prompt. It waits until the Automatic Shut Off time or until the operator responds. This parameter sets the time that the Terminal stops waiting on input from the operator, discards the current prompt, and goes back to the host to see if there is a change in instructions. If no change, the host must resend the prompt again because the Terminal has discarded the original prompt. The host now has the opportunity to change a prompt. The time can be set in increments of 5 seconds, up to 495 seconds. The default value is 00. The values possible for entry are 00-99. An entered 99 gives 99x5 seconds, or 495 seconds between check backs. The Terminal sends back an ASCII 07 for the data back to the host (ID ASCII 07 CR). This parameter's prompt is:

AUTOMATIC CHECK BACK

Key 00-99.

Current Value: 00

Code 3 of 9 (Code 39)

Bar Codes

Enable Code 3 of 9

0

Disable Code 3 of 9

1

Enable Full ASCII Code 39

2

Disable Full ASCII Code 39

3

Enable Code 39 Accumulate Mode

4

Disable Code 39 Accumulate Mode

5

Enable Start/Stop character transmission

6

Disable Start/Stop character transmission

7

Enable Mod 43 Check Digit

8

Disable Mod43 Check Digit

9

Enable Check Digit transmission

A

Disable Check Digit transmission

B

Caps Lock ON

C

Caps Lock OFF

D

The Start and Stop character for Code 39 is the * character. Settings 6 and 7 determine whether or not those characters are transmitted to the computer along with the data. For example, at setting 6, the data of 1234 would be transmitted as *1234*. Transmitting the start and stop

2-9

Image 18
Contents February 2006 Worth Data Inc Table of Contents Appendix C Appendix aAppendix B Appendix DUsing the RF Terminal keypad… InstallationInstallation Tips ComponentsPage Battery Life Indicator Finish, Sign Off Change Batteries Hit Any KeyMm/dd/yy hhmm Recharging the batteries Terminal Menu FunctionsTo change the AA batteries Checking Batteries Please Wait………Opening screen can be bypassed upon power up. See Chapter Setup Mode Site SurveyInstalling the 802 Terminal Utilities Software RF System Setup RF Terminal SetupRF Terminal Default Settings Default RF Terminal Configuration Using the bar code RF Terminal Setup MenuTerminal Voice Operations-2 Using the keypad to setup the RF TerminalRF Setup Batteries--4 BarCodes RS232RF Setup Group you will find the parameterServer IP Address RF Terminal Setup ParametersDevice IP Address Subnet MaskAuthentication WEP Encryption KeyControl Keys Only LCD Backlight Display Mode Backlight DurationSkip Opening Screens Speaker and Headphone Volume Controls Enter 0-9 for Volume Control Current Value isAutomatic Check Back Code 3 of 9 CodeKey Current Value UPC/EAN Code Codabar 5 CodeID character is transmitted in front of the bar code data 5 Length MSI and PlesseyRSS-14 Beep ToneBatteries Set Date Set TimeDisplay of Year Laser Scanner Options Voice Message PartitionsShut Down Time 303015Reset Aiming Dot DurationData Bits Baud RateParity Stop BitsLittle more in depth… Operational TheoryBasic RF System communications… Looking for Dhcp Server Please WaitWaiting for Prompt From Host Computer Can I change a prompt after it has been sent? Page Performance Issues Evaluating your area of planned operation65% Ssid80% 35%Page Page Before you begin programming… Operator Errors Failure PlanningHardware Failures Programming for the 802 RF Terminal IntroductionObjects, Properties, Methods, and Events Go to location Press enter when ready Pick Item YY qty N Scan barcode Enter Qty Picked WD802Term/ActiveX Programming ConsiderationsServer Communications Network SetupServer Shut Down Due to Host Logic Error WD802Term.InitializeServer WD802Term.ServerActive = TrueControl Keys for Possible Programming Test For Good CommunicationTerminal Tracking Concepts WD802Term ActiveX Properties WD802Term ActiveX999 Any valid file path and name 5000-65536True, False Through 2GBLine, position, prompt, shifted, timestamped Methods WD802Term ActiveXNone Line, position, promptEntry while scanning with the integrated laser Line, position, prompt, shiftedData Special Considerations Line CountMsgnum TermNumber Events WD802Term ActiveX TerminalTerminal, data One-for-one host prompt/terminal response OnTermLeftArrow Portable Printers Cameo and QL 320 Common InformationZebra Cameo Printer Zebra QL 320 Printer Track 1&2Part Number Description Price Roll Page Why Use Voice Messages and Prompts? Tips for Using Voice PromptsVoice Message Operations Terminal Setup-1 Voice Operations----2 RF Terminal’s Voice Message MappingProgramming Voice Messages Recording and Playback of Voice Messages Cloning Master Cloning ReceiverKEY R/P? Default Voice Messages Recv Setup/Voice Please Wait Xmit Setup/Voice Please WaitEnd of Cloning Hit Any Key Page System Test TroubleshootingGeneral Considerations Radio TestXXXBAT-zz% Terminal Error Messages MessageMeaning Action Required Unit won’t power up with batteries good batteries Troubleshooting specific problemsRF Terminal Problems My response time is poorReader wont beep when I try to read bar codes Problems reading Bar CodesGet 6 beeps when the RF Terminal powers up Have very poor read rates when scanning bar codesIf you have a problem… Worth Data Inc Swift St Santa Cruz, CA 95060Printer Pin-outs Laser and CCDRemember Page Firmware Upgrades Terminal Firmware UpgradesFirmware Download via Radio Link Serial Firmware Download for a Terminal Failsafe Firmware Download for a TerminalEnter Firmware Rev Number 3 digits Code 39 Specifications C39+ 2 + 3 + 33 + 34 + 35 = Code 39 Advanced Features and FunctionsMod 43 Check Character 108/43 = 2 with a RemainderFull Ascii Extension to Code Accumulate Mode Start/Stop Character onlyClear Enter Code 93 Specifications Page Codabar Specifications Codabar start/stop transmissionPage Code 128 Specifications UCC-128/ EAN-128UCC-128 Shipping Container Code Even Odd Interleaved 2 of 5 Code SpecificationsInterleaved 2 of 5 Mod 10 check digit calculation + 1 =60 57 = + 9 x 3 =+ 48 = 019873UPC / EAN Specifications Isbn Specifications Supplemental codesUPC/EAN checksum character Checksum calculation for UPC-A, EAN-13 and EAN-8UPC-E Checksum Calculation 01234500006+ 6 + 7 + 0 = MSI/Plessey Specifications835 x 2 = + 4 + 14 =+ 12 + 32 + 35 + 30 + 28 + 6 + 12 + 36 = 9434578424,5,6,7,2,3,4,5,6,7 195/11 = 17 remainderHow to scan a bar code Laser and CCD ScannersAiming the Laser Dot To return to the default 2-second beam, scanLaser Options To return to the single decode beam, scanDifficult Code 39 Reading Page Using the Scan Stand Page Laser Scanners Optional FeaturesCCD Scanners LI50 Linear Imager ScannerPSC Long Range Laser Laser AccessoriesLZ400 Laser Scanner H11 Laser HolderRF Terminal Cases and Holsters F41 Leather RF Terminal Carrying CaseT46 Holster for RF Terminal Rubber Boot for RF Terminal Ascii Code Equivalent Table BELPage Display Character Code Mapping Page RF Terminal Setup Menu UPC/EANDisable Codabar Ssid Resets current individual parameter Back to default settings Full Ascii Menu 056 057 058 059 060 061 062 063 064 065 066 067 +T* *+U* *+V* *+W Page Index EDI Label Code 4 Printer Setup Mode Upgrading firmware in Base,Relay or