Worth Data 802 RF Portable Printers, Cameo and QL 320 Common Information, Zebra Cameo Printer

Page 54

Portable Printers

Cameo and QL 320 Common Information

Both of these printers are stocked by Worth Data for the convenience of our users who need portable printing.

These printers do not require any special protocol; they do not require the “wake-up byte” as do other printers. They do require a special cable that

can be ordered from Worth Data (part #C12); cable pin-outs are available in Appendix C: Cable Pin-outs.

Shipped with every Cameo or QL 320 printer ordered is a CD ROM with the Programmers Manual in PDF format and a label design program – LabelVista. This program allows you to design the program and create multiple format files that can be sent to the printer where they become resident in flash. Variable fields are defined and can then be filled in by the program when in operation.

Keep in mind the following information when using these versatile printers:

The printer turn on ("Wake-up") is accomplished by the 802 RF Terminal toggling the DSR line on the printer, so only the @S command and the data you are sending to the printer is needed.

Once the 802 RF Terminal has turned on the printer, it stays on

until the host program turns it off using the POWER OFF COMMAND "ESC(0x1b)`p'(0x70)" described in the Printing Systems Programming Manual, or until the automatic shutdown takes place (2 minute default).

The 231 character limit applies to your command string. See your Portable Printing Systems Programming Manual for details on programming your printer.

Zebra Cameo Printer

The Zebra “Cameo ” Printers are portable direct thermal receipt printers, (not label printers – the QL 320 below prints labels). Bar codes can be printed on the receipts, but you can’t print labels.

One model of the Cameo printer is available with a magnetic stripe reader, allowing magnetic stripe input to the 802 RF Terminal using the @M (magstripe input) command.

The Cameo printer with magstripe input is capable of reading Track 1, Track 2 or Tracks 1&2. See your Portable Printing Systems Programming Manual for the correct character string to send in the @M command to turn on the magstripe reader. (see page 6-2 for details).

6-17

Image 54
Contents February 2006 Worth Data Inc Table of Contents Appendix C Appendix aAppendix B Appendix DUsing the RF Terminal keypad… InstallationInstallation Tips ComponentsPage Battery Life Indicator Finish, Sign Off Change Batteries Hit Any KeyMm/dd/yy hhmm Recharging the batteries Terminal Menu FunctionsTo change the AA batteries Checking Batteries Please Wait………Opening screen can be bypassed upon power up. See Chapter Setup Mode Site SurveyInstalling the 802 Terminal Utilities Software RF System Setup RF Terminal SetupRF Terminal Default Settings Default RF Terminal Configuration Using the bar code RF Terminal Setup MenuTerminal Voice Operations-2 Using the keypad to setup the RF TerminalRF Setup Batteries--4 BarCodes RS232RF Setup Group you will find the parameterServer IP Address RF Terminal Setup ParametersDevice IP Address Subnet MaskAuthentication WEP Encryption KeyControl Keys Only LCD Backlight Display Mode Backlight DurationSkip Opening Screens Speaker and Headphone Volume Controls Enter 0-9 for Volume Control Current Value isAutomatic Check Back Code 3 of 9 CodeKey Current Value UPC/EAN Code Codabar 5 CodeID character is transmitted in front of the bar code data 5 Length MSI and PlesseyRSS-14 Beep ToneBatteries Set Date Set TimeDisplay of Year Laser Scanner Options Voice Message PartitionsShut Down Time 303015Reset Aiming Dot DurationData Bits Baud RateParity Stop BitsLittle more in depth… Operational TheoryBasic RF System communications… Looking for Dhcp Server Please WaitWaiting for Prompt From Host Computer Can I change a prompt after it has been sent? Page Performance Issues Evaluating your area of planned operation65% Ssid80% 35%Page Page Before you begin programming… Operator Errors Failure PlanningHardware Failures Programming for the 802 RF Terminal IntroductionObjects, Properties, Methods, and Events Go to location Press enter when ready Pick Item YY qty N Scan barcode Enter Qty Picked WD802Term/ActiveX Programming ConsiderationsServer Communications Network SetupServer Shut Down Due to Host Logic Error WD802Term.InitializeServer WD802Term.ServerActive = TrueControl Keys for Possible Programming Test For Good CommunicationTerminal Tracking Concepts WD802Term ActiveX Properties WD802Term ActiveX999 Any valid file path and name 5000-65536True, False Through 2GBLine, position, prompt, shifted, timestamped Methods WD802Term ActiveXNone Line, position, promptEntry while scanning with the integrated laser Line, position, prompt, shiftedData Special Considerations Line CountMsgnum TermNumber Events WD802Term ActiveX TerminalTerminal, data One-for-one host prompt/terminal response OnTermLeftArrow Portable Printers Cameo and QL 320 Common InformationZebra Cameo Printer Zebra QL 320 Printer Track 1&2Part Number Description Price Roll Page Why Use Voice Messages and Prompts? Tips for Using Voice PromptsVoice Message Operations Terminal Setup-1 Voice Operations----2 RF Terminal’s Voice Message MappingProgramming Voice Messages Recording and Playback of Voice Messages Cloning Master Cloning ReceiverKEY R/P? Default Voice Messages Recv Setup/Voice Please Wait Xmit Setup/Voice Please WaitEnd of Cloning Hit Any Key Page System Test TroubleshootingGeneral Considerations Radio TestXXXBAT-zz% Terminal Error Messages MessageMeaning Action Required Unit won’t power up with batteries good batteries Troubleshooting specific problemsRF Terminal Problems My response time is poorReader wont beep when I try to read bar codes Problems reading Bar CodesGet 6 beeps when the RF Terminal powers up Have very poor read rates when scanning bar codesIf you have a problem… Worth Data Inc Swift St Santa Cruz, CA 95060Printer Pin-outs Laser and CCDRemember Page Firmware Upgrades Terminal Firmware UpgradesFirmware Download via Radio Link Serial Firmware Download for a Terminal Failsafe Firmware Download for a TerminalEnter Firmware Rev Number 3 digits Code 39 Specifications C39+ 2 + 3 + 33 + 34 + 35 = Code 39 Advanced Features and FunctionsMod 43 Check Character 108/43 = 2 with a RemainderFull Ascii Extension to Code Accumulate Mode Start/Stop Character onlyClear Enter Code 93 Specifications Page Codabar Specifications Codabar start/stop transmissionPage Code 128 Specifications UCC-128/ EAN-128UCC-128 Shipping Container Code Even Odd Interleaved 2 of 5 Code SpecificationsInterleaved 2 of 5 Mod 10 check digit calculation + 1 =60 57 = + 9 x 3 =+ 48 = 019873UPC / EAN Specifications Isbn Specifications Supplemental codesUPC/EAN checksum character Checksum calculation for UPC-A, EAN-13 and EAN-8UPC-E Checksum Calculation 01234500006+ 6 + 7 + 0 = MSI/Plessey Specifications835 x 2 = + 4 + 14 =+ 12 + 32 + 35 + 30 + 28 + 6 + 12 + 36 = 9434578424,5,6,7,2,3,4,5,6,7 195/11 = 17 remainderHow to scan a bar code Laser and CCD ScannersAiming the Laser Dot To return to the default 2-second beam, scanLaser Options To return to the single decode beam, scanDifficult Code 39 Reading Page Using the Scan Stand Page Laser Scanners Optional FeaturesCCD Scanners LI50 Linear Imager ScannerPSC Long Range Laser Laser AccessoriesLZ400 Laser Scanner H11 Laser HolderRF Terminal Cases and Holsters F41 Leather RF Terminal Carrying CaseT46 Holster for RF Terminal Rubber Boot for RF Terminal Ascii Code Equivalent Table BELPage Display Character Code Mapping Page RF Terminal Setup Menu UPC/EANDisable Codabar Ssid Resets current individual parameter Back to default settings Full Ascii Menu 056 057 058 059 060 061 062 063 064 065 066 067 +T* *+U* *+V* *+W Page Index EDI Label Code 4 Printer Setup Mode Upgrading firmware in Base,Relay or