Adams MDW-250L manual Adam Equipment Company Rev C5, January

Page 14

<p> Polarity character including minus sign for negative weight and a space character for positive weight

W1-W7 weight data

<dp> decimal point

U1U2: measure units, kg, lb

8.5.3Commands and response

(1)Command: W<CR> (57h 0dh)

Response:

<LF>^^^^^^u1u2<CR><LF>H1H2H3<CR><ETX>---over capacity

<LF>______u1u2<CR><LF> H1H2H3 <CR><ETX>---under capacity <LF>---------u1u2<CR><LF> H1H2H3<CR><ETX>---zero-point error

<L F><p >w1 w2 w3 w4 w5 w6 <dp >w7u1u 2 <CR><LF>H1H2 H3 <CR> <ETX> ---Scale is stable, and the current weight unit is kg or lb. With or without decimal point and the position is as per the P9 setting and current unit.

(2)Command: S<CR> (53h 0dh)

Response: <LF> H1H2H3<CR><ETX>

(3)Command: Z<CR> (5ah 0dh)

Response: Zero function is activated and it returns to current scale status, the same as pressing the ZERO/ON/OFF button:

<LF> H1H2H3<CR><ETX>

If ZERO function cannot be activated, it will return to current scale status.

(4)Command: T<CR> (54h 0dh)

Response: TARE function is activated, and then returns scale status. the same as pressing the TARE button:

<LF> H1H2H3<CR><ETX>

If TARE function cannot be activated, it will return to current scale status.

(5)Command: U<CR> (55h 0dh)

Response: Changes units of measure and returns scale status with new units, the same as pressing the UNIT button. The new measuring unit should be allowed to be used as per P11 setting.

<LF>u1u2<CR><LF> H1H2H3<CR><ETX>

(6)Command: X<CR> (58h 0dh)

Response: power off the scale the same as pressing the ON/OFF button to turn off the scale.

(7)Command: all others

Response: Unrecognized command <LF>?<CR><ETX>

© Adam Equipment Company 2012

Page 13

Rev C5, January 2012

Image 14
Contents MDW 250L Digital Health and Fitness ScaleAdam Equipment Company Rev C5, January Contents Adam Equipment Company Rev C5, January Technical Specifications IntroductionDisplay and KEY Descriptions Keys FunctionsSetting UP the Scale Function WeighingCalibration Measuring HeightAdam Equipment Company Rev C5, January User Parameters RS232 Communications When Parameter S.F. in is set to Adam Equipment Company Rev C5, January Adam Equipment Company Rev C5, January Error Messages Adam Equipment Company Rev C5, January Adam Equipment Company Rev C5, January Manufacturer’s Declaration of Conformity Adam Equipment Company Rev C5, January