KX-P7100
3.3.Laser Scanning Unit ( LSU )
Before handling, remove the Right, Left and Top Covers ( see Section 3.2 ).
(1)Remove the 3 screws.
(2)Disconnect the 2 connectors from the LSU.
3.4.Relay Board (B)
Before handling, remove the Left Cover ( see Section 3.2 ).
(1)Remove the connector from the Relay Board ( B ).
(2)Remove the 2 screws.
(3)Remove the Relay Board (B).
30