KX-P7100
Motor Driver True Table
IN 1 or 4 | IN 2 or 3 | OUT 1 or 4 | OUT 2 or 3 |
L | L | OFF | OFF |
L | H | L | H |
H | L | H | L |
H | H | OFF | OFF |
Note:
Motor Current will be cut off in case of “OFF” condition above.
Motor Driver True Table for Current Chopping Level
| I0 | I1 |
| Current ratio |
| |
| L | L | 100% |
| ||
| L | H | 33% |
| ||
|
|
| Motor Drive Mode |
|
|
|
Mode |
| Speed |
| Current ratio | ||
1st Hold for rotating |
| Stop |
| 33% |
| |
Warm Up |
| Full |
| 100% | ||
Printing (Plain Paper / Transparency) |
| Full |
| 100% | ||
Printing (Other Media) |
| Half |
| 100% | ||
Manual Feed (Catching a Paper) |
| Full |
| 100% | ||
If printing Data is more than approx. 2.5MB |
| Half |
| 100% | ||
Last Hold after rotating |
| Stop |
| 100% | ||
Stand by / Ready / Sleep / Error |
| Stop |
| OFF |
59