8 Preventative Maintenance
8.1.General
The preventative maintenance ( PM ) schedule is every 2,000 impressions. Adhering to this schedule will ensure maximum print quality and reduce machine downtime and service calls.
8.2.Recommended Tools
The following tools are recommended. | 3. | Cleaning alcohol | |
1. | Toner vacuum cleaner | 4. | Cleaning cotton |
2. | Blower brush | 5. | Cotton swabs |
8.3.Recommended Cleaning
1. Remove the OPC Drum Unit.
Caution :
When the OPC Drum Unit is removed, keep it covered to prevent light shock. Do not touch the black OPC drum surface.
2.Vacuum the inside of the machine after removing the OPC Drum Unit. Temporarily store the OPC Drum Unit in the protective bag.
3.Clean the rollers ( feed roller, pickup roller ) with alcohol.
Caution :
Do not use thinner or solvents; they will damage rubber and plastic components.
4.Clean the corona with a blower brush.
5.Clean the LSU cover glass with a dry
8.4.Maintenance Tables
8.4.1.User Maintenance
Replace these items according to the following schedule :
(x 1000 pages)
Item |
|
|
|
|
|
| Service |
|
|
|
|
|
|
|
| 4 | 8 | 12 | 16 | 20 | 24 | 28 | 32 | 36 | 40 | 44 | 48 |
| 180 |
Toner Cartridge | R | R | R | R | R | R | R | R | R | R | R | R |
| R |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
OPC Drum Unit |
|
|
|
| R |
|
|
|
| R |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| R: Replace |
95