Troubleshooting
Error Code/Message
Follow the instructions below when an error message or code appears. If the problem persists or if the error code/mes-
sage is not shown here, contact Panasonic Technical Support ( | page 36). | |||
|
|
|
|
|
Error Code/Message |
| Solution | ||
0211 Keyboard error | Disconnect external keyboard or mouse. | |||
0251 System CMOS | An error has occurred in the memory of Setup Utility settings. This occurs when the memory | |||
checksum bad - | content is changed by an unexpected program operation, etc. | |||
Default configuration | Start the Setup Utility and return the settings to the default values, and then change the | |||
used | settings as necessary. |
|
|
|
| If the problem persists, the internal clock battery may need to be replaced. Contact | |||
| Panasonic Technical Support ( | page 36). | ||
0271 Check date and | The date and time settings are not correct. | |||
time settings | Start the Setup Utility and set the correct date and time. | |||
| If the problem persists, the internal clock battery may need to be replaced. Contact | |||
| Panasonic Technical Support ( | page 36). | ||
0280 Previous boot | Startup has failed repeatedly, so the Setup Utility settings have been returned to the default | |||
incomplete - Default | values to startup the computer. |
|
|
|
configuration used | Start the Setup Utility and return the settings to the default values, and then change the | |||
| settings as necessary. |
|
|
|
Press <F2> to Setup | Write down the error details and press |
| to start the Setup Utility. Change the settings | |
F2 | ||||
| if necessary. |
|
|
|
0613: Serial Port*1 con- | The I/O and IRQ settings of the serial ports are in conflict. | |||
figuration changed | Run the Setup Utility and in the [Advanced] menu, change the port’s settings so there is | |||
0614: Serial Port*1 | no conflict. |
|
|
|
config. error - device |
|
|
|
|
disabled |
|
|
|
|
*1 “A” or “B” appears |
|
|
|
|
here to indicate the |
|
|
|
|
name of the conflict- |
|
|
|
|
ing port. |
|
|
|
|
Operating System not | The operating system is not installed in the floppy disk or the hard disk that you are going to | |||
found | boot from. |
|
|
|
| If using a floppy disk, change the disk to the one you can use for boot. | |||
| If using the hard disk, check if the hard disk is recognized in [Information] menu of the | |||
| Setup Utility. If the hard disk is recognized, perform the reinstallation ( page 22). If not, | |||
| contact Panasonic Technical Support ( page 36). | |||
| If a device is connected to the USB port, disconnect the device, or set [USB Port] or | |||
| [Legacy USB Support] to [Disable] in the [Advanced] menu of the Setup Utility. | |||
| If a device is connected to the ExpressCard slot, disconnect the device, or set | |||
| [ExpressCard slot] to [Disable] in the [Advanced] menu of the Setup Utility. | |||
RAM Module Failed | When the RAM module is not inserted correctly or the RAM module is not conforming to the | |||
| computer’s specifications, a beep will sound and the “RAM Module Failed” message will be | |||
| displayed when you turn the power on. | |||
| Slide the power switch for four seconds or longer to turn off the computer, confirm that | |||
| the RAM module conforms to the specifications, and reinsert it. |
To start the Setup Utility
ARestart the computer.
BPress F2 several times while [Panasonic] boot screen is displayed.