Cleaning and replacement of air filter

If too much dust accumulates on the air filter, [AIR FILTER] appears at the lower left of the screen, and the temperature monitor (TEMP) will blink once. If even more dust is allowed to accumulate, the temperature inside the main unit will rise, the temperature monitor (TEMP) will blink twice, and the power is turned off.

Clean the air filter section once every 100 hours or so as a guideline depending on the location of projector operation.

It appears only for 30 seconds within 3 minutes after the power is turned on. It disappears if any of the buttons on the rear side of the main unit or on the remote control is pressed.

Procedure of cleaning

Turn off the main power and remove the power plug from the receptacle.

Turn off the main power supply observing the procedure (Powering off the projector) on page 23 and then remove the power plug.

Dismantle the air filter.

There are two air filters, one at the left and one at the right.

Use your finger to pull the air filter tab toward you, and remove it from the main unit.

Clean the air filter.

Suck off deposited dust with a vacuum cleaner.

Air filter

Attention • Do not to suck in the air filter itself.

Do not rinse off the air filter with water. Doing so will impair the filter’s ability to provide protection from dust.

Set the air filter.

Set the air filter in the reverse order to step .

Attention • Fit the air filters into place with the filter material facing the back. (The left and right filters have the same shape.)

The air filter must be fitted in place when using the projector.

Using the projector without the air filter fitted inside, dirt and dust are sucked into the projector, causing failure.

Note • If cleaning cannot remove the dust completely, then it is a sign to replace the air filter. Consult the dealer. In addition, when the lamp unit is replaced, also replace the air filter.

Be absolutely sure to use the air filter specifically designed for use with the projector.

ENGLISH

41

Image 41
Contents Operating Instructions Model number PT-D5600E/PT-D5600EL/PT-DW5000E/PT-DW5000EL Dear Panasonic CustomerImportant the Moulded Plug U.K. only For Your SAFETY, Please Read the Following Text CarefullyContents Precautions with regard to safety Always disconnect all cables before moving the projector Do not place liquid containers on top of the projectorDo not insert any foreign objects into the projector Use only the specified battery AccessoriesDo not look into the lens while the projector is being used Do not use the old lamp unitPrecautions on handling Name and function of parts Set to Computer When the operation mode selectorStatus LED lights Front and side of the projectorRear view of the main unit Controls on rear panel Side-mounted connection terminals Loading dry cells Using the remote control unitEffective range of remote control operation Operation mode selector switch Setting projector ID number to remote controlUsing the remote control as a PC mouse Using a wired remote control InstallationInstallation geometry Projection schemesPT-D5600E, PT-D5600EL Projection distance by projection lensPT-DW5000E, PT-DW5000EL InstallationCalculation formulas for projection distance by lens types Connection Setup precautionsExample of connecting with PCs Example of connecting with AV productsProjection Powering up the projectorMaking adjustment and selection Direct power off function Powering off the projectorHow to remove the projection lens How to adjust the lensHow to adjust the lens position to the left or right Choose an item and adjust it using buttonsUsing the Freeze function Automatic adjustment Auto SetupUsing the Shutter function Using the digital zoom D.ZOOM + functionLanguageenglish On-screen menusStructure of menu screens Resetting to the factory default Menu items settingBasic menu operations Returning to the previousAdjusting the picture TV-SYSTEM Adjusting the positionSystem PositionKeystone Clock PhaseZoom Input Resolution How to use Advanced MenuDigital Cinema Reality BlankingSxga Mode XGA ModeRaster Position ENGLISH, DEUTSCH, FRANÇAIS, EspañolOPTION1 settings Lamp Power OPTION2 settingsFRONT/REAR DESK/CEILINGFAN CONTROL2 PasswordSystem Information FAN CONTROL1Setting the security Connecting the PC Setting the networkSystem requirements Connection examplePin assignments and signal names Using the serial terminalsCommunication conditions Factory setting Examples of connectionCable specifications Control commandsConnecting to a PC Computer Projector DTE specifications Pin assignments and controlIndication of lamp monitor Procedure of cleaning Cleaning and replacement of air filterClean the air filter Dismantle the air filterReplacing the lamp unit Timing of lamp unit replacementRemove the two screws securing the fan unit Lamp unit replacement stepsLamp unit will be hot after it has been used Have a Phillips screwdriver ready ahead of timeReplacing the lamp unit Accessing from the Web browser Using Web Browser ControlPassword change Click OKBasic control Network set up buttonChange password button Power On/Off control Shutter control Monitor information Detail controlInput AIR Temperature Error informationError Mail setupDNS server set up Mail setup page continuingPing test POP server setupAdjust clock Contents of mail sentNetwork status Network configSupported commands Using the PJLink protocolPJLink security authentication Command Control Description RemarksPower does Symptoms ChecksRemote control Not turn onPT-D5600E PT-D5600EL PT-DW5000E SpecificationsOutside dimensions Length of power supply cord CabinetRemote control Power source Wireless mouse receiverPAL-M/PAL60 PAL/PAL-N/SECAM Compatible Signal ListInstallation dimensions diagram DimensionsTrademark Acknowledgement For business users in the European Union