Interfaces

Serial (RS-232) Connector

Serial (RS-232) Connector

Pin No.

Description

 

 

1

Not used

 

 

2

RXD (receive data) input to the printer

 

 

3

TXD (transmit data) output from printer

 

 

4

DTR (data terminal ready) output from the printer -- controls when the

 

host may send data

 

 

5

Chassis ground

 

 

6

DSR (data set ready) input to the printer

 

 

7

RTS (request to send) output from the printer -- always in the ACTIVE

 

condition when the printer is turned on

 

 

8

CTS (clear to send) input to the printer

 

 

9

+5 V @ 0.75 A fused

 

 

The maximum current available through the serial and/or parallel port is not to exceed a total of 0.75 Amps.

When XON/XOFF handshaking is selected, data flow is controlled by the ASCII control codes DC1 (XON) and DC3 (XOFF). The DTR control lead will have no effect.

Interconnecting to DTE Devices The printer is configured as data terminal equipment (DTE). To connect the printer to other DTE devices (such as the serial port of a personal computer), use an RS-232 null modem (crossover) cable.

Interconnecting to DCE Devices When the printer is connected via its RS-232 interface to data communication equipment (DCE) such as a modem, a STANDARD RS-232 (straight- through) interface cable must be used.

58

LP 2824-Z User Guide

980531-001 A

Image 58
Contents User Guide Customer Order # 980531-001 a Product Improvements Proprietary StatementFCC Compliance Statement Liability Disclaimer Canadian DOC Compliance StatementLimitation of Liability Preface ContactsDocument Conventions Environmental ManagementSupport Related Documents Preface Contents Operations & Options Introduction HelloWhat’s in the Box? Inspecting the Printer Opening the printerAfter opening the printer, check the media compartment Closing the printer Reporting DamageIntroduction Getting Started Modes of PrintingAttaching Power Supply Adjusting the Roll Holders Loading Roll MediaPlacing the Roll in the Media Compartment Adjusting the Guides Feed Button Power SwitchOperator Controls Status LightPrinting a Test Label Hooking Up the Printer and Computer Interface Cable RequirementsCommunicating with the Printer Ethernet Interface RequirementsAdjusting the Print Width Adjusting the Print QualityOperations & Options Thermal Printing Replacing Supplies Printing in Peel-Mode XA MMP XZ XA JUS XZOperations & Options Printing on Fan-Fold Media Using the Cutter Option Operations & Options Maintenance CleaningPrint Head Considerations Media Path Considerations Sensors Lubrication Platen ConsiderationsReplacing the Platen RemovalReplacing the Print Head Thermal-Transfer LP Model Replacing the LP Print Head Maintenance Printer is not receiving power TroubleshootingResolutions Printer is on and in an idle statePrinter is receiving data Printer has failed its power on self test PostThere is a shortage of memory Either the media or ribbon is outPrint head is over temperature Print head is under temperatureFlash memory is not programmed No print on the label Print Quality ProblemsRibbon sensor settings did not print Printed image does not look rightLabel format was sent to, but not recognized by, the printer Manual Calibration Printing a Configuration Label Troubleshooting TestsRecalibration Resetting the Factory Default Values Communications DiagnosticsPower Off Mode Communications Diagnostics Mode Feed Button ModesBattery Universal Serial Bus USB Connector InterfacesParallel Interface 33-34ZebraNet PrintServer II for Ethernet Networks Rx+Serial RS-232 Connector Connecting the Printer to a DTE Device Interfaces Page Customer Order # 980531-001A 2004 ZIH Corp