Zebra Technologies TLP 2824 manual Print Quality Problems, No print on the label

Page 46

Print Quality Problems

No print on the label.

You must use the correct media for the method of printing you require. When printing without a ribbon, you must use direct thermal media. When using ribbon, you must use thermal transfer media. The printer's ribbon sensor detects motion of the supply spindle.

Is the media loaded correctly? Follow the instructions in “Loading the Media” on page 9.

The printed image does not look right.

The print head is dirty. Clean the print head according to the instructions on page 33.

The print head is under temperature.

Adjust the print darkness and/or print speed. Use the S and D commands in the programming guide.

The media being used is incompatible with the printer. Be sure to use the recommended media for your application, and always use manufacturer-approved labels and tags.

There are long tracks of missing print (blank vertical lines) on several labels.

The print head is dirty. Clean the print head according to the instructions on page 33.

The print head elements are damaged. Replace the print head (see “Replacing the Print Head” on page 32).

38

980485-001A

Image 46
Contents Zebra TLP 2824 TM 980485-001A Proprietary Statement Shock Hazard Contents Operation & Options 980485-001A Vii 980485-001A Introduction HelloWhat’s in the Box? Inspecting the Printer Opening the printerInspecting the Printer Closing the printer Related Documentation Reporting DamageGetting Started Modes of PrintingAttaching Power Supply Adjusting the Roll Holders Loading Roll MediaPlacing the Roll in the Media Compartment Adjusting the Guides Install the Take-Up Core Install the Ribbon Supply RollLoading Ribbon Attach and Tighten the Ribbon Feed Button Power SwitchOperator Controls Status LightMedia Length Sensing Hooking Up the Printer and Computer Interface Cable RequirementsEthernet Interface Requirements USB Interface RequirementsParallel Interface Requirements Serial Interface RequirementsParallel Communications Communicating with the PrinterUniversal Serial Bus USB Communications Internal ZebraNet PrintServer II Ethernet CommunicationsCommand Serial CommunicationsAdjusting the Print Width Adjusting the Print QualityOperation & Options Thermal PrintingAdding a New Transfer Ribbon Replacing SuppliesReplacing a Partially Used Transfer Ribbon Printing in Peel-Mode Printing on Fan-Fold Media Using the Cutter Option 980485-001A Maintenance CleaningPrint Head Considerations Cleaning Card ConsiderationsMedia Path Considerations Lubrication Platen ConsiderationsReplacing the Platen AssemblyRemoval Replacing the Print Head Thermal-Transfer TLP Model RemovalAssembly 980485-001A Troubleshooting What the Status Light is Telling YouPrinter Operation Media Handling No print on the label Print Quality ProblemsPrinted image does not look right Label format was sent to, but not recognized by, the printer Manual Calibration Resetting the Factory Default Values Communications DiagnosticsFeed Button Modes Printer Condition Feed Button ActionAppendix Universal Serial Bus USB ConnectorInterfaces Parallel Interface HostLooking into the Printer’s RJ-45 Modular Connector Internal Ethernet PrintServerSerial RS-232 Connector Serial RJ-11 Alternative Connector Printer980485-001A Page Page