Note the following information:

The maximum steady-state output power is limited to a total of 1140 W for any combination of output voltages/currents at low-line 100-120 VAC nominal input voltage conditions.

The maximum steady-state output power is limited to a total of 690 W for any combination of output voltages/currents, excluding the 50 VDC source at low-line 100-120VAC nominal input voltage conditions. This limitation is required to ensure that there is sufficient PoE power or 450 W total at this input voltage condition.

The maximum steady-state output power is limited to a total of 870W for any combination of output voltages/currents, excluding the 50 VDC source at high-line 200-240VAC nominal input voltage conditions. This limitation is required to ensure maximum PoE power or 900 W total for the 50 VDC source at this input voltage condition.

To obtain the full output power rating of 1770 W, you must connect the power supply to a nominal (200-240VAC) input voltage source.

The following table list the power specifications for the Ethernet Routing Switch 8302AC power supply.

Table 6

Ethernet Routing Switch 8302AC power specifications

AC Input Power Ratings

Input voltage range (nominal):

100-120 VAC

200-240 VAC

 

 

 

 

Input current (nominal):

12 A

9 A

 

 

 

 

Frequency range (nominal):

50-60 Hz

50-60 Hz

 

 

 

 

Input VA

1192 VA

1768

VA

 

 

 

 

Input power consumption:

1180 W

1750

W

 

 

 

 

Heat dissipation

1126BTU/hr

1195

BTU/hr

(thermal/output):

 

 

 

 

 

 

Hold-up time:

20 ms

20 ms

 

 

 

 

 

DC Output Power Ratings

 

 

 

 

 

Max. output power (combined):

850W (760W + 90W fans)

1400 W (1310W + 90W fans)

 

 

 

Non-PoE:

3.3 VDC @ 150 A

3.3 VDC @ 150 A

 

12 VDC @ 65 A

12 VDC @ 65 A

 

 

 

PoE:

50 VDC @ 18 A

50 VDC @ 18 A

 

 

 

Fans:

12 VDC @ 7.5 A

12 VDC @ 7.5 A

 

 

 

 

Nortel Ethernet Routing Switch 8300

Installation — AC Power Supply

NN46200-301 03.01 Standard

4.027 August 2007

Copyright © 2007, Nortel Networks

Image 24
Contents Installation AC Power Supply Restricted rights legend Statement of conditionsContents Contents Features New in this releaseOther changes New in this release Command line interfaces PrefacePreface Accessing the Nncli Text conventions Returning to the CLIHard-copy technical manuals Italic textHow to get help Power supply installation Power suppliesNavigation 8301AC power supply Power supply LEDs State Meaning Power supply installation Removing and installing a power filler panel Step ActionInstalling the AC power supply For instructions, see Removing the AC power supply Removing the AC power supply To remove an AC power supply End Appendix Electrical specifications for the AC power supply DC Output Power RatingsAppendix Electrical specifications for the AC power supply Appendix Electrical specifications for the AC power supply Appendix Electrical specifications for the AC power supply Page Installation AC Power Supply