Panamax M1500-UPS owner manual Advanced Setup Menu

Page 11

Home Cinema Power Control Software Instructions (continued)

ADVANCED SETUP MENU

1.Low Battery HTPC Shutoff: For use with a Home Theater PC. Sets the low battery cutoff level. The user can slightly extend the UPS run time by adjusting this setting. This setting must be higher than the Critical Load Threshold if the HTPC is plugged into a non-critical load outlet.

9.High-Voltage

Failure: Sets the

upper level where the UPS will cycle to battery. This level can be adjusted from 137V to 147V.

8.Low-Voltage Failure: Sets the lower

level where the UPS will cycle to battery. This level can be adjusted from 88V to 97V.

7.Battery-mode Output Voltage:

Sets the voltage that the unit will output. This level can be adjusted from 110V to 130V when running on battery.

2. Low Battery NCL Shutoff: NCL stands for Non- Critical Load. Sets the % of battery capacity at which all remaining battery power is reserved for the equipment plugged into the critical load outlet bank. Power to the 4 NCL outlets will be turned off at this point.

3. Cold Start: When this is enabled, the UPS can start in the absence of AC power. To maximize battery life, it is recommended to keep this disabled.

4.OK: Closes the windows and

saves changes.

5. Cancel: Closes

the window without saving changes.

6. Default:

Restores the settings to the factory defaults.

SCHEDULE MENU - SPECIAL

1.Special Setting: Allows

you to schedule a one-time shut- down/startup.

9. Turn On: Select

the day/date and time that you want the com- puter system to restart. Can only be used in conjunction with a scheduled shutdown.

8.Schedule Display: Window

display of the days/dates and times of any scheduled startups and shut- downs.

2. Weekly Setting: Allows you to schedule a shutdown and start up based upon the day of the week.

3.Turn Off: Select the day/date and time that you want the computer system to shutdown. This is optional and has no effect on whether your computer will shut down during a power failure.

4.OK: Closes the win- dow. Please note: You must click Add to add the item to the schedule.

5.Cancel: Closes

the window without saving any schedules even if one was added to the Schedule Display Window. Does not can- cel previously applied schedules.

6.Add: Adds an item to the schedule.

7.Delete: Clears the selected item from the schedule.

USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901

 

9

Image 11
Contents MAX Home Cinema UPS Before You Begin Table of ContentsModel # M1500-UPS Important Safety InstructionsFront Panel Description Installing Your UPSHardware Installation Guide Basic OperationRear Panel Description Front Panel Display LED DescriptionsLED Color Status Advanced OperationFor Windows 95/98/Me Home Cinema Power Control SoftwareSoftware Installation For Windows XP Home and Professional RS232 Control with Open ProtocolFor Windows NT For WindowsOverview Home Cinema Power Control Software InstructionsMain Menu Main Window Descriptions Setup MenuAdvanced Setup Menu LOG Menu Battery FeaturesTesting The Battery Backup Function Battery ReplacementRemove the four retaining screws DiagnosticsBattery Replacement Procedure Problem Possible Cause Solution TroubleshootingTechnical Specifications Communications Protocol RS232 Communications Protocol & Command SetController Commands Main Power OnRequest Outlet Status Set Low Battery NCL Non-Critical Load ShutoffEnable Audible Alarm Non Critical Load Outlets OnRequest Load Level Status Request Battery Charge Level StatusRequest Input Voltage Level Request Output Voltage StatusCondition Response from UPS Power Status MessagesInvalid Command or Query Responses and Warning Messages Outlet Bank Status MessagesFCC Notice Upgrade PolicyFCC Notice and Warranties INS0763 REV. B 7/05