MGE UPS Systems Comet TM 5 - 30 kVA user manual Comet series 31 general characteristics

Page 51

Comet series 31 general characteristics

apparent power (kVA):

5

7.5

10

15

20

active power (kW):

4

6

8

12

16

 

 

 

 

 

 

efficiency (%):

91

91

91

92

92

heat losses (W):

445

668

890

1335

1780

noise level (dBa):

 

 

 

 

 

on RL load:

45

46

46

50

50

on RCD load:

50

53

53

53

53

battery backup time (minutes):

 

 

 

 

 

at rated load (power factor 0.6):

8

10

10

10

10

maximum leakage current (mA):

 

 

 

 

 

directly earthed neutral system (TT):

5

11

11

24

24

during a fault with an impedent neutral system:

23

45

45

102

102

dimensions and weight

 

 

 

 

 

height (mm):

730

910

910

1085 1085

width (mm):

360

400

400

560

560

depth (mm):

420

550

550

680

680

weight (kg):

90

190

210

390

450

AC input

 

 

 

 

 

number of phases:

3

 

 

 

 

voltage (V):

323 to 444

 

 

 

frequency (Hz):

47 to 63

 

 

 

power factor:

> 0.95

 

 

 

current distortion (%):

< 26

 

 

 

 

inrush current:

< In

 

 

 

 

AC output

 

 

 

 

 

number of phases:

1

 

 

 

 

voltage (V):

220 / 230 / 240

 

 

voltage tolerance (%):

± 1

 

 

 

 

frequency (Hz):

50 / 60

 

 

 

frequency tolerance (free-running) (%):

± 0.1

 

 

 

 

frequency tolerance (synchronized) (%):

± 1 / ± 1.5 / ± 2 / ± 3 / ± 4

synchronization rate (Hz/s):

1 / 2

 

 

 

 

Merlin Gerin by MGE UPS SYSTEMS

Comet installation and user manual: E-6761200XT/FB

11.3

Image 51
Contents Comet 30 kVA Merlin GerinSafety recommendations Sikkerhedsforskrifter NorskRecomendações de segurança PortuguêsTurvallisuusohjeet SuomalainenSäkerhetsföreskrifter SvenskContents Glossary Maintenance and servicingOptions AppendicesIdentification plate Safety information Identification to CometConfiguration Introduction to CometKey for figures 2 to Functional diagramGeneral Final positioning figureComet layout seen from above Connection diagram for a single AC input InstallationSpecial precautions Electrical diagram for power connectionsConnection sequence for 5 kVA Comet Connection of power cables figures 10 toConnections for Comet series 31 5kVA Connections for Comet series 11 5kVAConnections for Comet series 11 7.5/10kVA Connection sequence for Comet other than 5kVAConnections for Comet series 33 10/15/20/30kVA Connections for Comet series 31 7.5/10/15/20kVAKey to figure Controls and indicationsBasic controls and indications Controls and indicationsThis light indicates that Comet is Inverter on button Inverter off button BuzzerDiagnostics display Controls and diagnostics display figureBuzzer reset Fault resetPreliminary checks Powering up to CometManual maintenance bypass switch Start-upInverter start-upsystem in manual start-up mode Powering down ShutdownInverter shutdown Merlin Gerin by MGE UPS Systems Operation on battery power figure OperationNormal operation Return of AC input power Battery durationInverter Overload curve Battery monitoring testsWhen an overload occurs Overloads on 5 kVA Comet S11 or S31Static bypass Overload curve Mains 2 out of tolerance Merlin Gerin by MGE UPS Systems Alarms Alarm indications tableStatus or action producing the indication End of battery power Battery circuit breaker in off positionManual bypass Chopper overtemperature see faultManual bypass switch Standard functions SUB-D 15-pin connector connectionSUB-D 15-pin connector CommunicationJbus / RS232 and Jbus / RS485 Monitor PlusContact TalkVisual check Maintenance and servicingSafety reminder Preventive maintenance by user Battery maintenanceMaintenance contracts Customer trainingAnnual check Extended battery cabinet Additional battery cell characterisiticsOptions Connection of an additional battery cabinet Connection of an additional battery cabinetConnection diagram for MX shunt trip to terminal block XR3 Emergency offShunt trip connection Full galvanic isolation transformer standard Comet equipment Power connection diagramsSeparate Mains 2 transformer AC bypass input Power connection diagramFrequency converter Hot standby system Harmonics filter Example of a Comet series Combined optionsFull isolation transformer and separate Mains 2 transformer Full isolation transformer and harmonics filterRelative positions of the various cubicles Separate Mains 2 transformer and harmonics filterGeneral characteristics Range characteristicsAppendices Comet series 11 general characteristics Comet series 31 general characteristics Comet series 33 general characteristics Selection of cable cross-sections Selection of protection devices Schematic diagram for protection devices11.7 Connection of the cable shielding Glossary 12.2 6761200XT MGE UPS Systems S.A

Comet TM 5 - 30 kVA specifications

MGE UPS Systems Comet TM 5 - 30 kVA is a reliable and efficient uninterruptible power supply (UPS) designed to ensure the smooth operation of critical systems in various applications. This UPS is particularly suited for data centers, telecommunications, and industrial environments that require high availability and robust power protection.

One of the main features of the Comet TM series is its modular design, which allows users to scale the UPS capacity as needed. This flexibility is crucial for businesses that anticipate growth or fluctuating power requirements. The UPS is available in a range of capacities, from 5 kVA to 30 kVA, allowing for tailored solutions that fit specific power needs.

The Comet TM is equipped with advanced double conversion technology, which provides clean and reliable power, isolating the connected equipment from input voltage disturbances. This technology ensures that any fluctuations in the mains supply, such as voltage sags or surges, do not affect the operation of sensitive electronic devices. Additionally, this UPS features a wide input voltage range that contributes to improved efficiency and reduced energy consumption.

An impressive aspect of the Comet TM is its high-efficiency mode, which optimizes energy consumption while maintaining power quality. This mode reduces operating costs and contributes to lower carbon footprints, making it an environmentally friendly choice. Furthermore, the UPS incorporates intelligent battery management systems, which enhance battery performance and extend their lifespan. This is essential in minimizing downtime and ensuring that backup power is readily available when needed.

The user-friendly interface of the Comet TM allows for easy monitoring and management of the system. With graphical displays and comprehensive alarms, users can promptly identify potential issues and take corrective actions. Remote management capabilities are also built into the system, enabling users to monitor and control the UPS remotely, which is particularly beneficial for businesses that operate across multiple locations.

In summary, the MGE UPS Systems Comet TM 5 - 30 kVA is designed for organizations that need reliable power protection and high efficiency. With its modular scalability, advanced double conversion technology, high-efficiency mode, intelligent battery management, and user-friendly interface, the Comet TM series stands out as a robust solution for critical power applications. Its combination of features ensures that businesses can maintain uninterrupted operations while benefiting from cost savings and a reduced environmental impact.