American Power Conversion MX28B2400+27V, MX28B1200 manual Snmp Interface, External Alarm Inputs

Page 32

MX28B-1200+27V PRODUCT MANUAL

Rev 1

The default passwords for level 1 and level 2 are “1111” and “2222”, respectively. There are no alternate passwords or “backdoors” for accessing the system. A forgotten password may require a

new master controller board, at customer expense.

System control parameters are stored in non-volatile memory and will not be erased when power is removed for the master control unit. However, if a new program EPROM is installed or a different device model selected, the system control parameters will be re-initialized to the factory default settings.

Eleven LEDs are provided on the front panel of the control unit to indicate system status. Three LEDs grouped together vertically provide overall system status; they are “MAJOR”, “MINOR”, and “NORMAL”, indicating the presence of a major alarm, a minor alarm, or normal operation. The other eight LEDs correspond to the active state of each of the alarm output relays and are labeled “ALM1”···“ALM6”, “MIN”, and “MAJ”.

6.2 SNMP Interface

In addition, the unit’s controller incorporates a 10-base T Ethernet connection to allow remote access to the system signals, and remote control of certain aspects of its operation. APC’s Manual #991- 0181 in the form of a CDRom will allow users to set up interface with the user’s Information Technology System. Simple Network Management Protocol (SNMP) version 1 is supported along with telnet protocol.

6.3 External Alarm Inputs

The four external alarm inputs (also referred to as “Input Relay Alarms”) can be assigned a priority and routed or “mapped” to alarm output relays. Available assignments are “Ignore”, “Major”, “Minor”, and “Relay 1” ··· “Relay 6”. Screens for making the assignments are located at [SYSTEM/IN-RLY/RLY-MAP]. This special menu notation is explained with an example in section 6.4

A user defined name or “alias” may also be assigned to each of these input alarms. Screens for making these assignments are located at [SYSTEM/IN-RLY/ALIAS]. For information on wiring connections to these inputs refer to Section 5.7.1.

6.4 Alarm Output Relays

There are eight alarm output relays designated Relay 1 through Relay 6, Minor, and Major, respectively. Various system parameters may be programmed to activate any of these alarm relays when set thresholds are exceeded or specific conditions occur. The first six relays can also be assigned a priority and routed or “mapped” to other output alarm relays. Available assignments are “Ignore”, “Major”, “Minor”, and “Relay 1” ··· “Relay 6”. Screens for making these assignments are located at [SYSTEM/OUT-RLY/RLY-MAP]. This feature makes it possible for a single alarm condition to activate multiple alarm output relays including the Minor or Major alarm relay. A user defined name or “alias” may also be assigned to each of the eight output relay alarms. Screens for making these assignments are located at [SYSTEM/OUT-RLY/ALIAS]. For information on making wiring connections to the alarm output relays refer to Section 5.7.2.

26

Image 32
Contents Model MX28B1200/2400+27V Battery Temperature Probe Description Part NumberDC Distribution Options +24V LVD Options +24VRevision Date Description 09/12/2001 Initial releaseTable of Contents SETUP, ADJUSTMENTS, and Operation Page Precautions IntroductionInspection upon Receipt of Goods GeneralConcealed Damage Return of Damaged GoodsGeneral Provisions Warranty ReturnsWarranty Repair or Replacement Exclusions and Limitations Description MX28B-1200/2400+27VMX28B1200/2400+27V System Diagram Converters Power Output CapacityRectifiers AC Input Power Control UnitBattery connections +24V DC Distribution48 V DC Distribution from Converters Optional DC DistributionCompliance EnvironmentalMechanical Safety Precautions PreparationRecommended Tools Recommended Test EquipmentRoom/Locations MountingAC Service and Ground Connections VentilationBattery Disconnect Connecting the Cables Cable Sizing ConsiderationsRectifier Installation Converter InstallationAlarm Connections Alarm Interface PC BoardExternal Alarm Inputs Alarm OutputsConnecting The Loads DC Circuit BreakersInstallation of Circuit Breakers 2.2 -48V Circuit Breaker Load ConnectionsBattery Temperature Probe Installation Power-Up and CheckoutApply AC Power System Parameters Verification/AdjustmentFull System Power Up SETUP, ADJUSTMENTS, and Operation User InterfaceSnmp Interface External Alarm InputsAlarm Output Relays Parameter Locations, Descriptions, and Default Values System SET-ALM AlarmsStatus Setup PIN DateOUT-RLY RLY-MAP AliasDiag Modules Rect SET-ALMParam InfoCirbkr SET-ALM Fuse SET-ALMComp Alias Fuse LVD SET-ALMBatt SET-ALM PIN OEM MX28B-1200+27V Product Manual RevParameter Description Display Screens Default Settings Conv LV Alm OFF 40.0 CBatt Disc Alm m+ Conv Fail Safem+ Cir Bkr 1 Alm m+ Out-Rly LVD1 LVD2

MX28B2400+27V, MX28B1200 specifications

The American Power Conversion (APC) MX28B1200 and MX28B2400+27V are advanced power management solutions designed to deliver superior reliability and performance for critical applications. These models are an integral part of APC’s extensive range of uninterruptible power supplies (UPS), catering specifically to high-performance environments such as data centers, server rooms, and industrial systems.

One of the standout features of the MX28 models is their robust power output capability. The MX28B1200 offers a 1200VA power rating, while the MX28B2400+27V boasts a substantial 2400VA rating. This impressive output ensures that connected equipment remains operational during power outages, providing essential backup support and minimizing downtime.

Another key characteristic is their advanced battery management technology, which incorporates intelligent charging systems to extend battery life and improve overall efficiency. This technology helps optimize the charging process, ensuring that the batteries are always in top condition and ready to supply power when needed.

The MX28B series also integrates smart LCD displays that provide real-time information on power conditions, battery status, and system performance. This user-friendly interface allows administrators to monitor the UPS at a glance, facilitating easier management and quicker response times in case of any issues.

In addition to reliable power delivery, the MX28 models emphasize scalability and flexibility. They are designed to support a variety of configurations and are compatible with a range of external battery packs. This ability to adapt means businesses can expand their power capabilities without overhauling their existing systems.

Furthermore, the MX28B series includes advanced protection features against power surges, voltage fluctuations, and other electrical disturbances. This ensures the safety of connected devices, safeguarding against potential damages and enhancing the overall integrity of critical operations.

The design of the APC MX28 models prioritizes efficiency, compliance with global energy standards, and reduced operational costs. This focus on efficiency not only leads to savings but also aligns with sustainable practices, making them an ideal choice for environmentally conscious organizations.

Overall, the APC MX28B1200 and MX28B2400+27V represent a significant advancement in UPS technology, combining power reliability, intelligent management, and environmentally friendly design to support a wide array of demanding applications across various industries.