American Power Conversion MX28B2400+27V, MX28B1200 manual LVD1, LVD2

Page 48

MX28B-1200+27V PRODUCT MANUAL

 

Rev 1

 

 

 

 

 

LVD Alarm

 

 

 

 

 

 

 

 

 

LVD1 Option {1}

Set to “Enable” if the unit has an LVD1.

LVD1

Option

m+

[MODULES/LVD/SET-ALM]

 

 

Enable

 

 

 

 

 

 

 

 

LVD1 Alarm {1}

Sets the priority or “mapping” of an LVD1 Alarm.

LVD1 Open Alm m+

[MODULES/LVD/SET-ALM]

 

 

Minor

 

 

 

 

 

 

 

 

 

 

LVD2 Option {1}

Set to “Enable” if the unit has an LVD2.

LVD2

Option

m+

[MODULES/LVD/SET-ALM]

 

 

Enable

 

 

 

 

 

 

 

 

LVD2 Alarm {1}

Sets the priority or “mapping” of an LVD2 Alarm.

LVD2 Open Alm m+

[MODULES/LVD/SET-ALM]

 

 

Minor

 

 

 

 

 

 

 

 

 

 

42

Image 48
Contents Model MX28B1200/2400+27V Battery Temperature Probe Description Part NumberDC Distribution Options +24V LVD Options +24VRevision Date Description 09/12/2001 Initial releaseTable of Contents SETUP, ADJUSTMENTS, and Operation Page Precautions IntroductionInspection upon Receipt of Goods GeneralConcealed Damage Return of Damaged GoodsWarranty Returns Warranty Repair or ReplacementGeneral Provisions Exclusions and Limitations Description MX28B-1200/2400+27VMX28B1200/2400+27V System Diagram Power Output Capacity RectifiersConverters AC Input Power Control UnitBattery connections +24V DC Distribution48 V DC Distribution from Converters Optional DC DistributionEnvironmental MechanicalCompliance Safety Precautions PreparationRecommended Tools Recommended Test EquipmentRoom/Locations MountingAC Service and Ground Connections VentilationBattery Disconnect Connecting the Cables Cable Sizing ConsiderationsRectifier Installation Converter InstallationAlarm Connections Alarm Interface PC BoardExternal Alarm Inputs Alarm OutputsConnecting The Loads DC Circuit BreakersInstallation of Circuit Breakers 2.2 -48V Circuit Breaker Load ConnectionsBattery Temperature Probe Installation Power-Up and CheckoutApply AC Power System Parameters Verification/AdjustmentFull System Power Up SETUP, ADJUSTMENTS, and Operation User InterfaceExternal Alarm Inputs Alarm Output RelaysSnmp Interface Parameter Locations, Descriptions, and Default Values Alarms StatusSystem SET-ALM Setup PIN DateOUT-RLY RLY-MAP AliasDiag Modules Rect SET-ALMParam InfoCirbkr SET-ALM Fuse SET-ALMAlias Fuse LVD SET-ALM Batt SET-ALMComp PIN OEM MX28B-1200+27V Product Manual RevParameter Description Display Screens Default Settings Conv LV Alm OFF 40.0 CBatt Disc Alm m+ Conv Fail Safem+ Cir Bkr 1 Alm m+ Out-Rly LVD1 LVD2