Troubleshooting
Problem | Probable Cause | Solution |
|
|
|
Circuit Breaker has tripped. | Reduce the amount of equipment plugged into the “Battery Backup + Surge Protection” | |
|
| outlets. Reset the circuit breaker by pushing it back in. |
| Utility power is not available at the wall | Ensure the fuse or circuit breaker for the wall outlet is okay, and the wall switch controlling |
| outlet. | the wall outlet (if any) is in the ON position. |
|
|
|
Connected equipment loses | The | Ensure the equipment plugged into the outlets of the unit are not overloading the capacity |
power. |
| of the unit. Try disconnecting some of the equipment one device at a time, and see if the |
|
| problem continues. |
| The | The unit can only operate on battery power for a limited amount of time. The unit will |
| battery power. | eventually turn off when the available battery power has been used. Allow the unit to |
|
| recharge for 10 hours before continuing to use the unit. |
| The equipment connected to the | The output waveform is designed for computers and |
| does not accept the | designed for use with |
| waveform from the unit. |
|
| The | Contact APC Technical Support for further troubleshooting. |
The ON/OFF button is lit, and | The unit is using battery. | The unit is operating normally and using battery power. Save any current work, turn off all |
the unit is beeping four times |
| equipment, and turn the unit OFF. Once normal power is restored, turn the unit back ON, |
every 30 seconds, or it is |
| and turn on all equipment. |
emitting a constant tone. |
|
|
|
|
|
The On/Off button flashes once | Battery capacity is low (there is about 2 | The unit is about to shut down due to a low battery charge condition! When the unit beeps |
per second, and the | minutes of use remaining). | once every second, the battery has about 2 minutes of power remaining. Immediately |
beeps once per second at the |
| power down your computer, and turn the unit OFF. When power returns to normal, the unit |
same time. |
| will recharge the battery. |
Inadequate runtime. | The battery is not fully charged. | Allow the unit to charge by leaving it plugged in, and switched on for 10 hours. |
| The battery is near the end of useful life. | As a battery ages, the amount of runtime available will decrease. Batteries also age |
|
| prematurely if the unit is placed near excessive heat. If the battery will not charge, the |
|
| |
|
|
|
Specifications
Input | Voltage | 230 Vac nominal | |
|
|
| |
| Frequency | ||
|
|
| |
| Brownout Transfer | 160 ±8% VAC, typical | |
|
|
| |
| 280 VAC, typical | ||
|
|
| |
Output | UPS Capacity (total) | 500 VA / 300 W | |
|
|
| |
| Voltage On Battery | 230 Vac rms | |
|
| ||
|
|
| |
| Frequency - On Battery | 50 Hz ±1 Hz, 60 Hz ±1 Hz | |
|
|
| |
| Transfer Time | 50 Hz: 6ms typical, 10ms maximum | |
|
| 60 Hz: 5ms typical, 8ms maximum | |
|
|
| |
Protection and | AC Surge Protection | Full time, 273 joules | |
Filter |
|
| |
AC Input | |||
| |||
|
|
| |
Battery | Type | Maintenance free | |
|
|
| |
| Average Life | 2 - 5 years depending on the number of discharge cycles and | |
|
| environmental temperature | |
|
|
| |
| Typical Recharge Time | 10 Hours | |
|
|
| |
Physical | Net Weight | 5.4 kg | |
|
|
| |
| Dimensions (H x W x D) | 18.55 cm (H) x 11.5 cm (W) x 21.3 cm (D) | |
|
|
| |
| Operating Temperature | 0 oC to 40 oC (32 oF to 104 oF) | |
| Storage Temperature | ||
| Operating Relative | 0 to 95% | |
| Humidity |
| |
|
|
| |
| Operating Elevation | 0 to 3000 m (0 to 10,000 ft) | |
|
|
|
Battery Replacement
The battery in the
Warranty
The standard warranty is 2 years from the date of purchase. The APC standard procedure is to replace the original unit with a factory reconditioned unit. APC will ship the replacement unit once the defective unit is received by the repair department or
Service
Please DO NOT RETURN
1.Consult the Troubleshooting section to eliminate common problems.
2.If you still have problems or questions, please contact APC via the internet or at one of the phone numbers listed below.
3.Before contacting APC, please be sure to record the date purchased, UPS model, and serial number (on bottom of unit).
4.Be prepared to troubleshoot the problem over the telephone with a Technical Support Representative. If this is not successful, the representative will issue a Return Material Authorization Number (RMA#) and a shipping address.
5.Pack the unit in its original packaging. If the original packaging is not available, ask APC Technical Support about obtaining a new set. Pack the unit properly to avoid damage in transit. Never use foam beads for packaging. Damage sustained in transit is not covered under warranty (insuring the package for full value is recommended).
6.Write the RMA# on the outside of the package.
7.Return the unit by insured carrier to the address given to you by APC Technical Support.
APC Worldwide Customer Support | Indonesia | 0800 1088 088 | ||
Malaysia | 1800 80 1030 | |||
Technical Support | http://www.apc.com/support | |||
Philippines | 1800 1651 0302 | |||
Internet | http://www.apc.com | |||
Singapore | +65 6389 6823 | |||
Worldwide | +1 800 555 2725 | |||
Thailand | 001 800 65 6340 | |||
|
| Vietnam | (1201 0288) 1 888 576 6432 |