Agilent Technologies 6011A, 6010a, 6012B, 6023A, 6028A manual Turn-On Checkout Procedure, Display OVP

Page 26

Number

Controls/Indicators

Table 3-1. Controls and Indicators

Description

Page

1

2

3

4

5

6

7

8

9

10

11

12

13

LINE Switch

VOLTAGE CONTROL

CURRENT CONTROL

OVP ADJUST

Voltage Display

Current Display

DISPLAYS SETTINGS Pushbutton Switch

DISPLAY OVP

Pushbutton Switch

CV Status Indicator

CC Status Indicator

UNREGULATED Status Indicator

OVERVOLTAGE Status Indicator

OVERTEMPERATURE Status Indicator

Pressing at the top of the switch applies ac mains voltage to the units bias and power circuits. Unit is operational approximately 3 seconds after power on.

Clockwise rotation increases the output voltage, 0 to full scale Vdc.

Clockwise rotation increases the output current, 0 to full scale Adc.

The recessed, single-turn screwdriver control sets the overvoltage protection trip voltage

A3-1/2-digit display with automatically positioned decimal point that can indicate output voltage, output voltage setting or overvoltage shutdown setting. During an error condition, the output may exceed the display range and the display will indicate + OL. A 3-1/2 digit display with automatically positioned decimal point that can indicate output current or output current setting. During an error condition, the output may exceed the display range, and the display will indicate + OL.

Causes numeric displays to indicate programmed voltage and current values, rather than actual output values; allows both settings to be made without the necessity of opening or shorting load.

Causes VOLTS display to indicate OVP trip voltage, AMPS display is blanked; allows setting to be made without changing output settings or load connections

CV (Constant Voltage) indicates that the power supply is regulating its output at a constant voltage.

CC (Constant Current) indicates that the power supply is regulating its output at a constant current.

UNR (Unregulated) indicates that the power supply is operating beyond its maximum output power specification and that the output is not regulated or has been shutdown by a protective circuit.

OV (Overvoltage) indicates that the power supply output has been shut down and latched by the occurrence of an overvoltage condition. Removing the cause of the overvoltage and turning the supply off and back on will reset the unit.

OT (Over temperature) indicates an overheating condition on either the diode or FET boards. OT automatically resets when the temperature drops to a safe operating level.

27

27

27

30

27

27

33, 34

33, 34

33

34

31, 32

31

31

Turn-On Checkout Procedure

WARNING: Before the instrument is turned on, all protective earth terminals, extension cords, and devices connected to the power supply should be connected to a protective earth ground. Any interruption of the protective earth grounding will cause a potential shock hazard that could result in personal injury.

Caution: This instrument can be damaged by electrostatic discharge into the control connectors, or the switches on the rear panel even while the unit is turned on. Do not cause an electrostatic discharge into these connectors and switches (which may occur when they are touched). Also, consistent with good engineering practice, leads attached to customer accessible signal/monitoring ports should be twisted and shielded to maintain the instruments specified performance.

The following procedure ensures that the supply is operational, and may be used as an incoming inspection check.

26 Operating Instructions

Image 26
Contents USER’S Guide Certification Safety Summary Safety Symbols Product Names Safety InformationManufacturer’s Name and Address Model NumbersHerstellerbescheinigung Manufacturer’s DeclarationTable Of Contents VAC Input Power Option IndexIntroduction Safety ConsiderationsGeneral Information DescriptionFor Agilent Models 6023A and 6028A AccessoriesOption Description Agilent Part No DescriptionOrdering Additional Manuals Related Documents SpecificationsInstrument and Manual Identification 6010A Performance SpecificationsSupplemental Characteristics Agilent Technologies Model 6011A6023A 6012B6015A 6028AShipping Supplemental CharacteristicsTemperature Rating C CertificationOutput Characteristic Curve General Information Output Impedance General Information Preparation for Use InstallationInitial Inspection Rack Mounting Outline DiagramsInput Power Requirements Agilent Models 6023A and 6028A Power ConnectionAgilent Models 6010A, 6011A, 6012B and 6015A Line Voltage Option Conversion Agilent 6010A, 6011A, 6012B Line Voltage Conversion Components Installation Model Voltage AC Line Impedance CheckRepackaging for Shipment Agilent Model 6023A and 6033A Rear Panel Screw Sizes and Part NumbersDescription Agilent Part number Front-Panel Controls and Indicators Operating Instructions Operating InstructionsTurn-On Checkout Procedure Display OVPOperating Instructions Initial Setup and Interconnections Connecting the LoadWire Size Maximum Wire Lengths To Limit Voltage DropsStranded Copper Wire Ampacity Connecting a Bypass Capacitor Overvoltage Protection OVP Protective ShutdownNormal Mode Operating ModesDetermining Operating Point Overrange Operation Constant Voltage Operation Remote Voltage Sensing Constant Current OperationVoltage change due to open sense lead BothAnalog Programming Constant Voltage Output, Resistance ControlVoltage Programming of Output Voltage Operating Instructions = Handle Auto-Parallel Operation Multiple-Supply OperationConstant Current Output, Voltage Control 12. Auto-Parallel Operation Series OperationMonitor Signals 13. Series OperationPage General Information VAC Input Power OptionUsing Appendix a Manual ChangesManual Changes Index Index Europe Japan Agilent Sales and Support OfficeUnited States Canada Latin America Australia/New ZealandManual Updates
Related manuals
Manual 126 pages 62.23 Kb

6015A, 6023A, 6028A, 6012B, 6011A, 6010a specifications

Agilent Technologies, a leader in the field of measurement and analysis, offers a suite of instruments within its 6010 and 6011 series, specifically the 6010A, 6011A, 6012B, and 6015A models. These devices are designed to meet the needs of various industries, including healthcare, environmental monitoring, and materials testing.

The Agilent 6010A is a high-performance spectrometer known for its precision and versatility. It utilizes advanced optical technologies to provide exceptional wavelength accuracy and resolution. This model is particularly useful in laboratories where reliable data is critical, offering a wide spectral range and effective noise reduction features. Its user-friendly interface simplifies complex analyses, making it suitable for both seasoned professionals and newcomers.

Following closely, the Agilent 6011A is recognized for its robust capabilities in laboratory environments. This device incorporates advanced signal processing techniques, enabling high-throughput measurements without compromising on quality. The 6011A is ideal for real-time monitoring applications, ensuring that users can make informed decisions based on accurate, timely data. Its comprehensive software suite is designed to enhance data analysis, allowing for seamless integration with existing laboratory workflows.

The 6012B variant enhances the functionality further by introducing additional features tailored for specific applications. With a focus on flexibility, the 6012B supports multiple measurement modes, including direct and differential detection. This model excels in complex measurements, allowing for greater analytical depth and insights. The built-in calibration options ensure consistent performance, making it a reliable choice for various research and development tasks.

Lastly, the Agilent 6015A model stands out with its leading-edge technology, designed for the most demanding applications. It boasts enhanced sensitivity and an improved dynamic range, making it perfect for trace analysis in challenging environmental samples. The 6015A’s advanced reporting tools provide detailed analytics, helping scientists and researchers interpret results efficiently. Its compact design also makes it suitable for laboratory spaces with limited room, without sacrificing performance.

Together, these models showcase Agilent Technologies' commitment to delivering high-quality, innovative solutions that empower users to achieve their analytical goals effectively and efficiently. Whether in a research, clinical, or industrial setting, the 6010A, 6011A, 6012B, and 6015A continue to set standards in precision instrumentation.