Constant Current Output, Voltage Control.

The setup shown in Figure 3-11 allows the output current to be varied by using an external voltage to program the supply. A voltage source variable from 0 to + 5 volts produces a proportional output current from zero to full scale. The static load on the programming voltage source is less than 5μA. A source resistance of less than 10k is necessary to avoid degradation of offset and drift specifications.

Note: If external resistors are used to limit the remote-programming voltage to 5Vdc, the resulting high programming-source resistance can degrade the power supply’s programming speed, offset and drift performance. Limit the equivalent source resistance to 10k ohm maximum. Figure 3-9 shows a convenient way to calculate suitable voltage-divider resistance values for a 5k ohm source resistance.

= Handle

Figure 3-11. Voltage Programming of Output Current

Multiple-Supply Operation

The power supply can be operated in combination with other power supplies to provide increased output capability. Auto- parallel operation of two power supplies can provide up to twice the output current. Other configurations are possible. Contact Agilent Technologies, Power Products Division for specific application assistance.

Auto-Parallel Operation

Two units can be connected in an auto-parallel combination to provide twice the output current capability. One of the power supplies, the master, is programmed normally. The other power supply, the slave, is analog programmed by the master. The mode switches of the slave must be set so that the slave is analog programmed by the master. Figure 3-12 shows the rear- panel mode switch settings and terminal connections for auto-parallel operation.

Operating Instructions 39

Image 39
Contents USER’S Guide Certification Safety Summary Safety Symbols Model Numbers Safety InformationManufacturer’s Name and Address Product NamesManufacturer’s Declaration HerstellerbescheinigungTable Of Contents Index VAC Input Power OptionDescription Safety ConsiderationsGeneral Information IntroductionAgilent Part No Description AccessoriesOption Description For Agilent Models 6023A and 6028ASpecifications Instrument and Manual IdentificationOrdering Additional Manuals Related Documents 6011A Performance SpecificationsSupplemental Characteristics Agilent Technologies Model 6010A6028A 6012B6015A 6023ACertification Supplemental CharacteristicsTemperature Rating C ShippingOutput Characteristic Curve General Information Output Impedance General Information Installation Initial InspectionPreparation for Use Outline Diagrams Input Power RequirementsRack Mounting Power Connection Agilent Models 6010A, 6011A, 6012B and 6015AAgilent Models 6023A and 6028A Line Voltage Option Conversion Agilent 6010A, 6011A, 6012B Line Voltage Conversion Components Installation AC Line Impedance Check Repackaging for ShipmentModel Voltage Rear Panel Screw Sizes and Part Numbers Description Agilent Part numberAgilent Model 6023A and 6033A Operating Instructions Front-Panel Controls and Indicators Operating InstructionsDisplay OVP Turn-On Checkout ProcedureOperating Instructions Connecting the Load Initial Setup and InterconnectionsMaximum Wire Lengths To Limit Voltage Drops Stranded Copper Wire AmpacityWire Size Protective Shutdown Connecting a Bypass Capacitor Overvoltage Protection OVPOperating Modes Normal ModeDetermining Operating Point Overrange Operation Constant Voltage Operation Constant Current Operation Remote Voltage SensingBoth Voltage change due to open sense leadConstant Voltage Output, Resistance Control Analog ProgrammingVoltage Programming of Output Voltage Operating Instructions = Handle Multiple-Supply Operation Constant Current Output, Voltage ControlAuto-Parallel Operation Series Operation 12. Auto-Parallel Operation13. Series Operation Monitor SignalsPage Manual Changes VAC Input Power OptionUsing Appendix a General InformationManual Changes Index Index Latin America Australia/New Zealand Agilent Sales and Support OfficeUnited States Canada Europe JapanManual Updates
Related manuals
Manual 126 pages 62.23 Kb

6015A, 6023A, 6028A, 6012B, 6011A, 6010a specifications

Agilent Technologies, a leader in the field of measurement and analysis, offers a suite of instruments within its 6010 and 6011 series, specifically the 6010A, 6011A, 6012B, and 6015A models. These devices are designed to meet the needs of various industries, including healthcare, environmental monitoring, and materials testing.

The Agilent 6010A is a high-performance spectrometer known for its precision and versatility. It utilizes advanced optical technologies to provide exceptional wavelength accuracy and resolution. This model is particularly useful in laboratories where reliable data is critical, offering a wide spectral range and effective noise reduction features. Its user-friendly interface simplifies complex analyses, making it suitable for both seasoned professionals and newcomers.

Following closely, the Agilent 6011A is recognized for its robust capabilities in laboratory environments. This device incorporates advanced signal processing techniques, enabling high-throughput measurements without compromising on quality. The 6011A is ideal for real-time monitoring applications, ensuring that users can make informed decisions based on accurate, timely data. Its comprehensive software suite is designed to enhance data analysis, allowing for seamless integration with existing laboratory workflows.

The 6012B variant enhances the functionality further by introducing additional features tailored for specific applications. With a focus on flexibility, the 6012B supports multiple measurement modes, including direct and differential detection. This model excels in complex measurements, allowing for greater analytical depth and insights. The built-in calibration options ensure consistent performance, making it a reliable choice for various research and development tasks.

Lastly, the Agilent 6015A model stands out with its leading-edge technology, designed for the most demanding applications. It boasts enhanced sensitivity and an improved dynamic range, making it perfect for trace analysis in challenging environmental samples. The 6015A’s advanced reporting tools provide detailed analytics, helping scientists and researchers interpret results efficiently. Its compact design also makes it suitable for laboratory spaces with limited room, without sacrificing performance.

Together, these models showcase Agilent Technologies' commitment to delivering high-quality, innovative solutions that empower users to achieve their analytical goals effectively and efficiently. Whether in a research, clinical, or industrial setting, the 6010A, 6011A, 6012B, and 6015A continue to set standards in precision instrumentation.