Agilent Technologies 6023A, 6028A, 6010a, 6011A Overrange Operation Constant Voltage Operation

Page 33

Figure 3-5. Overrange Operation

Constant Voltage Operation

By pressing the DISPLAY SETTINGS pushbutton switch you can observe the setting (limits) of both the output voltage and the output current, rather than the actual output values. This you set the current limit when the power supply is operating in CV mode, or set the voltage limit while in CC mode, without having to disconnect or adjust the load.

To set up the power supply for constant voltage operation:

a.With power supply turned off, connect the load to the output terminals.

b.Turn on power supply. Hold in DISPLAY OVP pushbutton switch and set OVP ADJUST potentiometer for the desired OVP trip voltage.

c.Hold DISPLAY SETTINGS pushbutton switch in and rotate CURRENT control to set desired current limit.

d.Adjust output voltage to desired level. The CV indicator should be on.

e.If a load change causes the current limit to be exceeded, the power supply automatically crosses over to constant current operation (CC indicator will come on) and the output voltage drops proportionately. In setting the current limit, make adequate allowance for high current peaks that could cause unwanted mode crossover.

Operating Instructions 33

Image 33
Contents USER’S Guide Certification Safety Summary Safety Symbols Manufacturer’s Name and Address Safety InformationProduct Names Model NumbersManufacturer’s Declaration HerstellerbescheinigungTable Of Contents Index VAC Input Power OptionGeneral Information Safety ConsiderationsIntroduction DescriptionOption Description AccessoriesFor Agilent Models 6023A and 6028A Agilent Part No DescriptionSpecifications Instrument and Manual IdentificationOrdering Additional Manuals Related Documents Supplemental Characteristics Agilent Technologies Model Performance Specifications6010A 6011A6015A 6012B6023A 6028ATemperature Rating C Supplemental CharacteristicsShipping CertificationOutput Characteristic Curve General Information Output Impedance General Information Installation Initial InspectionPreparation for Use Outline Diagrams Input Power RequirementsRack Mounting Power Connection Agilent Models 6010A, 6011A, 6012B and 6015AAgilent Models 6023A and 6028A Line Voltage Option Conversion Agilent 6010A, 6011A, 6012B Line Voltage Conversion Components Installation AC Line Impedance Check Repackaging for ShipmentModel Voltage Rear Panel Screw Sizes and Part Numbers Description Agilent Part numberAgilent Model 6023A and 6033A Operating Instructions Front-Panel Controls and Indicators Operating InstructionsDisplay OVP Turn-On Checkout ProcedureOperating Instructions Connecting the Load Initial Setup and InterconnectionsMaximum Wire Lengths To Limit Voltage Drops Stranded Copper Wire AmpacityWire Size Protective Shutdown Connecting a Bypass Capacitor Overvoltage Protection OVPOperating Modes Normal ModeDetermining Operating Point Overrange Operation Constant Voltage Operation Constant Current Operation Remote Voltage SensingBoth Voltage change due to open sense leadConstant Voltage Output, Resistance Control Analog ProgrammingVoltage Programming of Output Voltage Operating Instructions = Handle Multiple-Supply Operation Constant Current Output, Voltage ControlAuto-Parallel Operation Series Operation 12. Auto-Parallel Operation13. Series Operation Monitor SignalsPage Using Appendix a VAC Input Power OptionGeneral Information Manual ChangesManual Changes Index Index United States Canada Agilent Sales and Support OfficeEurope Japan Latin America Australia/New ZealandManual Updates
Related manuals
Manual 126 pages 62.23 Kb

6015A, 6023A, 6028A, 6012B, 6011A, 6010a specifications

Agilent Technologies, a leader in the field of measurement and analysis, offers a suite of instruments within its 6010 and 6011 series, specifically the 6010A, 6011A, 6012B, and 6015A models. These devices are designed to meet the needs of various industries, including healthcare, environmental monitoring, and materials testing.

The Agilent 6010A is a high-performance spectrometer known for its precision and versatility. It utilizes advanced optical technologies to provide exceptional wavelength accuracy and resolution. This model is particularly useful in laboratories where reliable data is critical, offering a wide spectral range and effective noise reduction features. Its user-friendly interface simplifies complex analyses, making it suitable for both seasoned professionals and newcomers.

Following closely, the Agilent 6011A is recognized for its robust capabilities in laboratory environments. This device incorporates advanced signal processing techniques, enabling high-throughput measurements without compromising on quality. The 6011A is ideal for real-time monitoring applications, ensuring that users can make informed decisions based on accurate, timely data. Its comprehensive software suite is designed to enhance data analysis, allowing for seamless integration with existing laboratory workflows.

The 6012B variant enhances the functionality further by introducing additional features tailored for specific applications. With a focus on flexibility, the 6012B supports multiple measurement modes, including direct and differential detection. This model excels in complex measurements, allowing for greater analytical depth and insights. The built-in calibration options ensure consistent performance, making it a reliable choice for various research and development tasks.

Lastly, the Agilent 6015A model stands out with its leading-edge technology, designed for the most demanding applications. It boasts enhanced sensitivity and an improved dynamic range, making it perfect for trace analysis in challenging environmental samples. The 6015A’s advanced reporting tools provide detailed analytics, helping scientists and researchers interpret results efficiently. Its compact design also makes it suitable for laboratory spaces with limited room, without sacrificing performance.

Together, these models showcase Agilent Technologies' commitment to delivering high-quality, innovative solutions that empower users to achieve their analytical goals effectively and efficiently. Whether in a research, clinical, or industrial setting, the 6010A, 6011A, 6012B, and 6015A continue to set standards in precision instrumentation.