TM-C100 Technical Reference Guide
Appendix A
Product Specifications of the TM-C100
A.1 Product Specifications
Item | Specification |
|
|
|
|
|
|
Interface (compatible) | USB |
|
|
|
| ||
Power supply | Power supply with a dedicated AC adapter | ||
|
| ||
Input voltage (rated) | Input voltage (rated) 90 (100 - 10%) to 264 (230 + 15%) VAC | ||
|
|
|
|
Frequency (rated) | 47 to 63 Hz |
|
|
|
|
|
|
Power consumption | Operating | Average: | Approximately 11 W |
|
| Peak: | Approximately 13 W |
| Idling | Average: | Approximately 1 W |
|
|
| |
Applicable standards | Europe: | CE marking EMC Directive: 89/336/EEC | |
|
| EN55022 Class B | |
|
| EN55024 |
|
|
| ||
|
| ||
|
| ||
|
| ||
|
| ||
|
| ||
|
| Safety standard: TÜV (EN 60950) | |
|
|
| |
| North | EMI: | |
| America: | Safety Standard: UL 60950/CSA C22.2 No. 60950 | |
|
|
| |
| Oceania: | EMC: AS/NZS 3548/CISPR22 Class B | |
|
|
| |
| Japan: | EMI: VCCI Class A | |
|
|
|
|
Reliability | Product | Mechanism | 12,000,000 passes (6,000,000 carriage returns) |
| lifetime: | Print head | 1,600,000,000 shots/nozzle |
|
|
| (Shots are the numbers of pulses energized for the print |
|
|
| head.) |
|
| Autocutter | Plain paper, special fine paper 350,000 cuts |
|
|
| Special matte paper, plain borderless label paper |
|
|
| 200,000 cuts |
|
| ASF | 200,000 sheets |
|
|
| (The end of product lifetime is when the printer reaches |
|
|
| the start of the |
|
| ||
MTBF | 180,000 hours (Failure is defined as a random failure occurring during the random | ||
| failure period.) |
| |
|
|
| |
MCBF | 30,000,000 passes |
| |
| This is an average failure interval based on failures relating to wearout and random | ||
| failures up to the life of 12,000,000 passes. | ||
|
|
| |
Temperature and humidity | Printing: | 10 to 35ºC, 20 to 80% RH no condensation | |
| Storage: | Packaged for shipping | |
|
|
| (Ink not loaded) |
|
|
| (within 120 hours at |
|
| Ink loaded | |
Absolute maximum rated | 70ºC (This temperature must NOT be exceeded whenever it is operating or in | ||
temperature | storage.) |
|
|
|
|
| |
Pressure (elevation) | Printing: | 775 to 1,050 hPa (corresponding to 0 to 2,000 m above sea level) | |
| Operating: | 700 to 1,060 hPa (corresponding to 0 to 2,500 m above sea level) | |
|
|
|
|
Rev. C | Product Specifications of the |