Agilent Technologies N-Series user manual Emulation Change, Selecting a UDK

Page 26

XES COMMANDS

45Page-

 

Selecting a UDK

When selecting a UDK, the trigger =UDK= must be entered in uppercase, exactly as shown. Any printable character may be used as the UDK, except:

uppercase U

uppercase D

uppercase K

comma (,)

null (0)

space (20h)

equal sign (=)

The UDK selected should also be one that is not required for printing, since the UDK cannot be printed. As such, the user should not select any alphanumeric character. No control characters are allowed to be assigned as the UDK.

Emulation Change

The X/TRA XLi will ordinarily receive XES data and convert it to PCL5 data, so that the data stream can be sent to the printer. However, the user may also need to send PCL, PostScript or another non-XES data stream to the printer without translation. To do so, the user must first use the XES command for changing printer emulation modes. To change emulation modes, XES uses the “Mode Change Keyword” command, which takes the following format to change to PCL and PostScript emulations, respectively:

=MCK= EMULATE/PCL/ENDd

=MCK= EMULATE/POSTSCRIPT/ENDd

Note: The =MCK= command sequence MUST be followed by a space

Image 26
Contents Agile Revision date 5 NovemberUser’s Manual Copyright InformationRelease Notes About This Manual FCC/DOC Statement Table of Contents Forms and Graphics Support ResetPrinters Supported Conversion MethodsOperator Text Message Tabs HorizontalXtraedit Configuration Configure Menu Install Settings Now Alt-I Install As New Configuration General Information Features and OptionsSpecifications 512K Flash Standard 256K RAM Firmware upgrades via provided PC/MSDOS softwareTwo-year product warranty Toll-free tech support is available from 730 AM. to 4 PMElectrical Requirements Prior to InstallationSelecting a Location Operating EnvironmentUnpacking N17 InstallationPackage Contents Printer PreparationInserting the X/TRA XLi N17Returning the Printer to Operation N24/N32/N40 Installation Place with wire latches Reconnect power cordInserting the X/TRA XLi Returning the Printer to Operation TRA XLi Connection to Parallel Input ConnectionsConnection Test If the Printer does not Return a Status Sheet TroubleshootingIf Printer does not Start TRA XLi XES Features and Specifications Introduction to XESTitan10iso Titan12iso XCP14iso Xerox DocuPrint N17, N24, N32, N40Forms downloading Vector graphics Raster graphics PC/MS DOS menu-driven configuration program Xtraedit Xerox Data Monitor Mode emulation Configuration/StatusXES Commands User-Defined KeysEmulation Change Selecting a UDK46Page User’s Manual Job Control Commands Non-Job Control Commands XES Command FormatJob Control Commands Two Types of Escape SequencesLine Endings Configuration/StatusNon-Job Control Commands 48Page User’s ManualJob Boundary Commands Optional CommentPrint Job Mixed Orientation Command s+XdPrint Job Page410 User’s ManualPrint Multiple Copies Non-Collated Miscellaneous CommandsPrint Multiple Copies Collated Paper TrayDuplex Start Output TrayOffset Duplex Invert StartComment Duplex StopDuplex Side Select Font Unload Font CommandsFont Load Font AddFont Change Formatting CommandsFont ID Assignment Units 1/60Units 1/300 Command szfCommand smH,T,B,L,Rd Range See chart MarginsMargin Left Margin TopMargin Bottom Margin RightTabs Clear Horizontal Command st#1,#2,...#64dCommand sd Page418 User’s ManualTabs Vertical Command sv#1,#2,...#64dCommand se Tabs Clear VerticalJustification Unlimited Justification StartJustification Stop Center Command sqCommand si# Range Line SpacingLine Spacing Absolute Command sip#dCommand sqzs#Cd Character Spacing AbsoluteText Placement Absolute Forms Creation CommandsBaseline Placement Absolute Command sza#1,#2dtextd Range See BelowPage424 User’s Manual Portrait Landscape Text Placement RelativeCommand srC1#C2 Range See Below For up For down For left For rightCommand sb Document Enhancement CommandsCommand sxor yX,Y,L,W,Sd Range See Below Line Draw X or YOverstrike Stop Bold StopOverstrike Start Subscript StartUnderline Start Superscript StartSub/Superscript Stop Merge Page Unload Underline StopMerge Page Load Form ID AssignmentForm Merge Stop Form Merge StartCycleforms Merge StartGraphic Window Command szdMerge Stop Page430 User’s ManualGraphic Delete Graphic Window RepeatPage432 User’s Manual Graphic LineGraphic Arc Range T=1-15Graphic Box Graphic Pie ChartCommand sgbTX1,Y1,X2,Y2d Range See Below Language Character ReassignmentLoad Translation Table Command s+D Data MonitorContol Codes Page436 User’s ManualAbout Xtraedit Getting StartedLoading Xtraedit Select Port Page538 User’s ManualXtraedit Configuration Xtraedit Main ScreenPage540 User’s Manual Keyboard CommandsF10=Menu Enter=OK/Select Item Esc=Cancel/Previous MenuOther Keyboard Commands Alt-X=ExitPage542 User’s Manual File MenuXLI Resources Directory Configure Menu Exit Alt-XSelect Configuration to Edit Page54 User’s ManualChange Default Configuration Font Selection Text GenerationPage546 User’s Manual Font RotationLine Spacing LanguageCharacter Set Absolute Line SpacingInput Tray Selection Printer SetupPage548 User’s Manual Input Paper SizeOutput Tray Map Input Tray MapOutput Tray Selection Source Code Page5-0 User’s ManualTwo-up Printing Duplex Length Portrait, LandscapeTop Offset Page5-2 User’s ManualSize Correction Minimum Left Coordinate Left OffsetMinimum Top Coordinate Top Margin Margins Portrait, LandscapePage5-4 User’s Manual Left Margin Tabs Portrait, LandscapeBottom Margin Right MarginPage5-6 User’s Manual Page5-7 Other Options Page5-8 User’s ManualEmulation Mode Line EndUnits of Measure Uppercase CommandsJob Timeout UDK CharacterError Level Undo Settings Alt-UInstall Settings Now Alt-I Resources Menu Install As New ConfigurationDelete Configuration Page562 User’s ManualView Installed Fonts Load FontPage564 User’s Manual Load Resources File Delete FontNon-Shrinkable Fonts Pack XLI Memory Command Line InterfaceSave Resources to File Page56 User’s ManualPreferences Menu Measurement Units for EntriesConfirm Before Updating XLI Page568 User’s ManualContents Help Menu

N-Series specifications

Agilent Technologies N-Series is a sophisticated family of next-generation instruments designed primarily for analytical and measurement applications in laboratories and industrial environments. The N-Series comprises a range of devices tailored for diverse sectors, including chemical analysis, life sciences, and material sciences. This series is recognized for its high precision, versatility, and advanced technological integration.

One of the key features of the N-Series is its exceptional performance in measurement accuracy and reliability. Utilizing state-of-the-art sensors and algorithms, these instruments deliver precise results, enabling users to conduct sensitive analyses with confidence. The N-Series also incorporates advanced automation capabilities, allowing for increased throughput and reduced human error during testing processes.

The N-Series benefits from innovative technologies such as digital signal processing and connectivity options, which enhance data acquisition and analysis capabilities. By employing cutting-edge algorithms, these devices can process complex data sets efficiently, providing comprehensive insights into various samples' characteristics. The integration of connectivity features, including USB and Ethernet connectivity, allows seamless communication with external devices, facilitating data sharing and remote monitoring.

Moreover, the N-Series is designed with user experience in mind. These instruments come equipped with intuitive interfaces, simplifying operation and enhancing user navigation. The touch-screen displays offer easy access to functions, while the built-in software provides advanced analytical tools and customizable reporting options. This focus on user-friendliness ensures that both experienced professionals and new users can operate the devices with ease.

Another notable characteristic of the N-Series is its robust construction and reliability under challenging conditions. Built to withstand demanding laboratory environments, these instruments demonstrate resilience, ensuring long-term performance and reduced downtime.

In summary, Agilent Technologies N-Series stands out as a leading solution in analytical instrumentation, providing users with advanced technology, exceptional accuracy, and user-friendly operation. Its comprehensive features cater to diverse measurement needs across various scientific fields, making it an invaluable tool for researchers and industry professionals alike. The ongoing evolution of the N-Series reflects Agilent's commitment to innovation and excellence in analytical solutions, paving the way for more precise and efficient laboratory work worldwide.