Agilent Technologies N-Series Font Commands, Font Load, Font Unload, Font Add, Font Delete

Page 35

Page414-

User’s Manual

pressed on the console. The XLi will neither display the message nor hold printing, but it will ensure that the message is not printed.

Font Commands

This section describes commands that affect fonts.

Font Load

COMMAND: s+F,commentd

RANGE:

132 characters for optional comment

The “Font Load” command is a job boundary command that erases all previously downloaded fonts and starts downloading a new set of fonts. Up to 121 fonts may be downloaded and up to 255 stored in the XLi FLASH RAM, if font size and available memory permit. This command will also delete the current merge page from memory.

Font Unload

COMMAND: s+U,commentd

RANGE:

132 characters for optional comment

The “Font Unload” command is a job boundary command that deletes all previously downloaded fonts.

Font Add

COMMAND: s+A,commentd

RANGE:

132 characters for optional comment

The “Font Add” command is a job boundary command that adds fonts to those already downloaded without erasing any previously downloaded fonts. Up to 121 fonts may be downloaded and up to 255 stored in the XLi FLASH RAM, if font size and available memory permit.

Font Delete

COMMAND: s+B,fontname1,2,nd

RANGE: N/A

Image 35
Contents Revision date 5 November AgileUser’s Manual Copyright InformationRelease Notes About This Manual FCC/DOC Statement Table of Contents Conversion Methods ResetPrinters Supported Forms and Graphics SupportTabs Horizontal Operator Text MessageXtraedit Configuration Configure Menu Install Settings Now Alt-I Install As New Configuration General Information Features and OptionsSpecifications Toll-free tech support is available from 730 AM. to 4 PM Firmware upgrades via provided PC/MSDOS softwareTwo-year product warranty 512K Flash Standard 256K RAMOperating Environment Prior to InstallationSelecting a Location Electrical RequirementsPrinter Preparation N17 InstallationPackage Contents UnpackingN17 Inserting the X/TRA XLiReturning the Printer to Operation Place with wire latches Reconnect power cord N24/N32/N40 InstallationInserting the X/TRA XLi Returning the Printer to Operation TRA XLi Connection to Parallel Input ConnectionsConnection Test If the Printer does not Return a Status Sheet TroubleshootingIf Printer does not Start Introduction to XES TRA XLi XES Features and SpecificationsTitan10iso Titan12iso XCP14iso Xerox DocuPrint N17, N24, N32, N40Forms downloading Vector graphics Raster graphics Xerox Data Monitor Mode emulation Configuration/Status PC/MS DOS menu-driven configuration program XtraeditUser-Defined Keys XES CommandsSelecting a UDK Emulation Change46Page User’s Manual Two Types of Escape Sequences XES Command FormatJob Control Commands Job Control Commands Non-Job Control Commands48Page User’s Manual Configuration/StatusNon-Job Control Commands Line EndingsOptional Comment Job Boundary CommandsPage410 User’s Manual Command s+XdPrint Job Print Job Mixed OrientationPaper Tray Miscellaneous CommandsPrint Multiple Copies Collated Print Multiple Copies Non-CollatedDuplex Invert Start Output TrayOffset Duplex StartComment Duplex StopDuplex Side Select Font Add Font CommandsFont Load Font UnloadUnits 1/60 Formatting CommandsFont ID Assignment Font ChangeMargins Command szfCommand smH,T,B,L,Rd Range See chart Units 1/300Margin Right Margin TopMargin Bottom Margin LeftPage418 User’s Manual Command st#1,#2,...#64dCommand sd Tabs Clear HorizontalTabs Clear Vertical Command sv#1,#2,...#64dCommand se Tabs VerticalJustification Unlimited Justification StartJustification Stop Line Spacing Command sqCommand si# Range CenterCharacter Spacing Absolute Command sip#dCommand sqzs#Cd Line Spacing AbsoluteCommand sza#1,#2dtextd Range See Below Forms Creation CommandsBaseline Placement Absolute Text Placement AbsoluteFor up For down For left For right Text Placement RelativeCommand srC1#C2 Range See Below Page424 User’s Manual Portrait LandscapeLine Draw X or Y Document Enhancement CommandsCommand sxor yX,Y,L,W,Sd Range See Below Command sbSubscript Start Bold StopOverstrike Start Overstrike StopUnderline Start Superscript StartSub/Superscript Stop Form ID Assignment Underline StopMerge Page Load Merge Page UnloadMerge Start Form Merge StartCycleforms Form Merge StopPage430 User’s Manual Command szdMerge Stop Graphic WindowGraphic Window Repeat Graphic DeleteRange T=1-15 Graphic LineGraphic Arc Page432 User’s ManualGraphic Box Graphic Pie ChartCommand sgbTX1,Y1,X2,Y2d Range See Below Language Character ReassignmentLoad Translation Table Data Monitor Command s+DPage436 User’s Manual Contol CodesAbout Xtraedit Getting StartedLoading Xtraedit Page538 User’s Manual Select PortXtraedit Main Screen Xtraedit ConfigurationPage540 User’s Manual Keyboard CommandsF10=Menu Alt-X=Exit Esc=Cancel/Previous MenuOther Keyboard Commands Enter=OK/Select ItemPage542 User’s Manual File MenuXLI Resources Directory Exit Alt-X Configure MenuPage54 User’s Manual Select Configuration to EditChange Default Configuration Font Rotation Text GenerationPage546 User’s Manual Font SelectionAbsolute Line Spacing LanguageCharacter Set Line SpacingInput Paper Size Printer SetupPage548 User’s Manual Input Tray SelectionOutput Tray Map Input Tray MapOutput Tray Selection Source Code Page5-0 User’s ManualTwo-up Printing Length Portrait, Landscape DuplexTop Offset Page5-2 User’s ManualSize Correction Minimum Left Coordinate Left OffsetMinimum Top Coordinate Top Margin Margins Portrait, LandscapePage5-4 User’s Manual Right Margin Tabs Portrait, LandscapeBottom Margin Left MarginPage5-6 User’s Manual Page5-7 Page5-8 User’s Manual Other OptionsLine End Emulation ModeUDK Character Uppercase CommandsJob Timeout Units of MeasureError Level Undo Settings Alt-UInstall Settings Now Alt-I Page562 User’s Manual Install As New ConfigurationDelete Configuration Resources MenuLoad Font View Installed FontsPage564 User’s Manual Load Resources File Delete FontNon-Shrinkable Fonts Page56 User’s Manual Command Line InterfaceSave Resources to File Pack XLI MemoryMeasurement Units for Entries Preferences MenuPage568 User’s Manual Confirm Before Updating XLIHelp Menu Contents

N-Series specifications

Agilent Technologies N-Series is a sophisticated family of next-generation instruments designed primarily for analytical and measurement applications in laboratories and industrial environments. The N-Series comprises a range of devices tailored for diverse sectors, including chemical analysis, life sciences, and material sciences. This series is recognized for its high precision, versatility, and advanced technological integration.

One of the key features of the N-Series is its exceptional performance in measurement accuracy and reliability. Utilizing state-of-the-art sensors and algorithms, these instruments deliver precise results, enabling users to conduct sensitive analyses with confidence. The N-Series also incorporates advanced automation capabilities, allowing for increased throughput and reduced human error during testing processes.

The N-Series benefits from innovative technologies such as digital signal processing and connectivity options, which enhance data acquisition and analysis capabilities. By employing cutting-edge algorithms, these devices can process complex data sets efficiently, providing comprehensive insights into various samples' characteristics. The integration of connectivity features, including USB and Ethernet connectivity, allows seamless communication with external devices, facilitating data sharing and remote monitoring.

Moreover, the N-Series is designed with user experience in mind. These instruments come equipped with intuitive interfaces, simplifying operation and enhancing user navigation. The touch-screen displays offer easy access to functions, while the built-in software provides advanced analytical tools and customizable reporting options. This focus on user-friendliness ensures that both experienced professionals and new users can operate the devices with ease.

Another notable characteristic of the N-Series is its robust construction and reliability under challenging conditions. Built to withstand demanding laboratory environments, these instruments demonstrate resilience, ensuring long-term performance and reduced downtime.

In summary, Agilent Technologies N-Series stands out as a leading solution in analytical instrumentation, providing users with advanced technology, exceptional accuracy, and user-friendly operation. Its comprehensive features cater to diverse measurement needs across various scientific fields, making it an invaluable tool for researchers and industry professionals alike. The ongoing evolution of the N-Series reflects Agilent's commitment to innovation and excellence in analytical solutions, paving the way for more precise and efficient laboratory work worldwide.