Agilent Technologies N-Series user manual Change Default Configuration

Page 66

XTRAEDIT CONFIGURATION

 

 

Page545-

 

 

 

 

 

 

 

Configuration

Size Correction

Orientation

Emulation

 

 

 

 

 

 

 

 

0

Shrink

Portrait

XES Mode

 

 

1

Shrink

Landscape

XES Mode

 

 

2

Offset

Portrait

XES Mode

 

 

3

Offset

Landscape

XES Mode

 

 

4

Shrink

Portrait

Passthrough

 

 

5

Shrink

Landscape

Passthrough

 

 

6

Offset

Portrait

Passthrough

 

 

7

Offset

Landscape

Passthrough

 

 

 

 

 

 

 

Page orientation implies the following set of parameters in the default configuration (discussed later in this section):

Orientation

Portrait

Landscape

 

 

 

Font Selection

Titan10iso-P

XCP14iso-L

Page Length

3300

2550

Top Margin

200

120

Bottom Margin

200

120

Left Margin

120

200

Right Margin

2430

3100

Top Margin, 2nd Page

200

120

Bottom Margin, 2nd Page

200

120

Left Margin, 2nd Page

120

200

Right Margin, 2nd Page

2430

3100

Horizontal Tabs

17 set

23 set

Vertical Tabs

15 set

11 set

 

 

 

In addition, all configurations have Top Offset and Left Offset settings of -75. Finally, all configurations have Job Sheet settings of Power/Error, with the error level set to Parse.

Change Default Configuration

From among the ten possible configurations, the user can select one to use as the default, or powerup, configuration. The default is Configuration 0, but the user can choose any configuration from 0-9. The number selected is constantly displayed in the box in the upper right corner of the screen next to Default powerup config.:.

Image 66
Contents Agile Revision date 5 NovemberCopyright Information Release NotesUser’s Manual About This Manual FCC/DOC Statement Table of Contents Forms and Graphics Support ResetPrinters Supported Conversion MethodsOperator Text Message Tabs HorizontalXtraedit Configuration Configure Menu Install Settings Now Alt-I Install As New Configuration Features and Options SpecificationsGeneral Information 512K Flash Standard 256K RAM Firmware upgrades via provided PC/MSDOS softwareTwo-year product warranty Toll-free tech support is available from 730 AM. to 4 PMElectrical Requirements Prior to InstallationSelecting a Location Operating EnvironmentUnpacking N17 InstallationPackage Contents Printer PreparationInserting the X/TRA XLi N17Returning the Printer to Operation N24/N32/N40 Installation Place with wire latches Reconnect power cordInserting the X/TRA XLi Returning the Printer to Operation Connections Connection TestTRA XLi Connection to Parallel Input Troubleshooting If Printer does not StartIf the Printer does not Return a Status Sheet TRA XLi XES Features and Specifications Introduction to XESXerox DocuPrint N17, N24, N32, N40 Forms downloading Vector graphics Raster graphicsTitan10iso Titan12iso XCP14iso PC/MS DOS menu-driven configuration program Xtraedit Xerox Data Monitor Mode emulation Configuration/StatusXES Commands User-Defined KeysEmulation Change Selecting a UDK46Page User’s Manual Job Control Commands Non-Job Control Commands XES Command FormatJob Control Commands Two Types of Escape SequencesLine Endings Configuration/StatusNon-Job Control Commands 48Page User’s ManualJob Boundary Commands Optional CommentPrint Job Mixed Orientation Command s+XdPrint Job Page410 User’s ManualPrint Multiple Copies Non-Collated Miscellaneous CommandsPrint Multiple Copies Collated Paper TrayDuplex Start Output TrayOffset Duplex Invert StartDuplex Stop Duplex Side SelectComment Font Unload Font CommandsFont Load Font AddFont Change Formatting CommandsFont ID Assignment Units 1/60Units 1/300 Command szfCommand smH,T,B,L,Rd Range See chart MarginsMargin Left Margin TopMargin Bottom Margin RightTabs Clear Horizontal Command st#1,#2,...#64dCommand sd Page418 User’s ManualTabs Vertical Command sv#1,#2,...#64dCommand se Tabs Clear VerticalJustification Start Justification StopJustification Unlimited Center Command sqCommand si# Range Line SpacingLine Spacing Absolute Command sip#dCommand sqzs#Cd Character Spacing AbsoluteText Placement Absolute Forms Creation CommandsBaseline Placement Absolute Command sza#1,#2dtextd Range See BelowPage424 User’s Manual Portrait Landscape Text Placement RelativeCommand srC1#C2 Range See Below For up For down For left For rightCommand sb Document Enhancement CommandsCommand sxor yX,Y,L,W,Sd Range See Below Line Draw X or YOverstrike Stop Bold StopOverstrike Start Subscript StartSuperscript Start Sub/Superscript StopUnderline Start Merge Page Unload Underline StopMerge Page Load Form ID AssignmentForm Merge Stop Form Merge StartCycleforms Merge StartGraphic Window Command szdMerge Stop Page430 User’s ManualGraphic Delete Graphic Window RepeatPage432 User’s Manual Graphic LineGraphic Arc Range T=1-15Graphic Pie Chart Command sgbTX1,Y1,X2,Y2d Range See BelowGraphic Box Character Reassignment Load Translation TableLanguage Command s+D Data MonitorContol Codes Page436 User’s ManualGetting Started Loading XtraeditAbout Xtraedit Select Port Page538 User’s ManualXtraedit Configuration Xtraedit Main ScreenKeyboard Commands F10=MenuPage540 User’s Manual Enter=OK/Select Item Esc=Cancel/Previous MenuOther Keyboard Commands Alt-X=ExitFile Menu XLI Resources DirectoryPage542 User’s Manual Configure Menu Exit Alt-XSelect Configuration to Edit Page54 User’s ManualChange Default Configuration Font Selection Text GenerationPage546 User’s Manual Font RotationLine Spacing LanguageCharacter Set Absolute Line SpacingInput Tray Selection Printer SetupPage548 User’s Manual Input Paper SizeInput Tray Map Output Tray SelectionOutput Tray Map Page5-0 User’s Manual Two-up PrintingSource Code Duplex Length Portrait, LandscapePage5-2 User’s Manual Size CorrectionTop Offset Left Offset Minimum Top CoordinateMinimum Left Coordinate Margins Portrait, Landscape Page5-4 User’s ManualTop Margin Left Margin Tabs Portrait, LandscapeBottom Margin Right MarginPage5-6 User’s Manual Page5-7 Other Options Page5-8 User’s ManualEmulation Mode Line EndUnits of Measure Uppercase CommandsJob Timeout UDK CharacterUndo Settings Alt-U Install Settings Now Alt-IError Level Resources Menu Install As New ConfigurationDelete Configuration Page562 User’s ManualView Installed Fonts Load FontPage564 User’s Manual Delete Font Non-Shrinkable FontsLoad Resources File Pack XLI Memory Command Line InterfaceSave Resources to File Page56 User’s ManualPreferences Menu Measurement Units for EntriesConfirm Before Updating XLI Page568 User’s ManualContents Help Menu

N-Series specifications

Agilent Technologies N-Series is a sophisticated family of next-generation instruments designed primarily for analytical and measurement applications in laboratories and industrial environments. The N-Series comprises a range of devices tailored for diverse sectors, including chemical analysis, life sciences, and material sciences. This series is recognized for its high precision, versatility, and advanced technological integration.

One of the key features of the N-Series is its exceptional performance in measurement accuracy and reliability. Utilizing state-of-the-art sensors and algorithms, these instruments deliver precise results, enabling users to conduct sensitive analyses with confidence. The N-Series also incorporates advanced automation capabilities, allowing for increased throughput and reduced human error during testing processes.

The N-Series benefits from innovative technologies such as digital signal processing and connectivity options, which enhance data acquisition and analysis capabilities. By employing cutting-edge algorithms, these devices can process complex data sets efficiently, providing comprehensive insights into various samples' characteristics. The integration of connectivity features, including USB and Ethernet connectivity, allows seamless communication with external devices, facilitating data sharing and remote monitoring.

Moreover, the N-Series is designed with user experience in mind. These instruments come equipped with intuitive interfaces, simplifying operation and enhancing user navigation. The touch-screen displays offer easy access to functions, while the built-in software provides advanced analytical tools and customizable reporting options. This focus on user-friendliness ensures that both experienced professionals and new users can operate the devices with ease.

Another notable characteristic of the N-Series is its robust construction and reliability under challenging conditions. Built to withstand demanding laboratory environments, these instruments demonstrate resilience, ensuring long-term performance and reduced downtime.

In summary, Agilent Technologies N-Series stands out as a leading solution in analytical instrumentation, providing users with advanced technology, exceptional accuracy, and user-friendly operation. Its comprehensive features cater to diverse measurement needs across various scientific fields, making it an invaluable tool for researchers and industry professionals alike. The ongoing evolution of the N-Series reflects Agilent's commitment to innovation and excellence in analytical solutions, paving the way for more precise and efficient laboratory work worldwide.