Fuse Configuration
The main fuse(s) on the AVERY DENNISON 676 LKP are located inside the AC power entry receptacle. The entry has a fuse drawer that holds the fuse(s) and selects the appropriate line voltage. If the number in the window DOES NOT match the AC line intended to be supplied to the printer, DO NOT plug the power cord in. Re configure as follows:
1)Using a flat blade screwdriver, open the AC entry by lifting the tab just above the voltage indicator window.
WARNING: Attempting to open the AC entry with the AC power cord inserted into it will cause damage to the AC entry.
2)Remove the red fuse drawer.
3)Remove all fuses and the fuse jumper if it is present.
4)Insert into the fuse drawer the correct number and style of fuses and fuse jumper for your application.
Configuration Number One: | Line voltage between the range of |
| 90 - 132VAC @ 50 - 60Hz 1 Ph |
1)Install one 921167 - 10.0A 250V Fast Acting 1/4 x 1 1/4"
2)Install one Fuse Jumper
See Figure FUSE1
Configuration Number Two: | Line voltage between the range of |
| 180 - 265VAC @ 50 - 60Hz 1 Ph |
1) Install two 921168 10.0A 250V Fast Acting 5 x 20MM
NOTE: The fuse jumper must be removed to install both 5 x 20mm fuses.
The fuses must be between points A and B as shown not B and C.
See Figure FUSE2
FUSE 1
Fuse Jum per
FRONT
Location of115V Text
Location of230V Text
FUSE 2
5 x 20 m m fuse
A | B | C |
FRONT
Location of115V Text
Location of230V Text
One 1/4 x 1 1/4" Fuse Far Side | Two 5 x 20MM Fuses One Each Side |
5)Reinsert the fuse drawer into the AC entry with the desired voltage up.
6)Close the AC entry and verify the correct voltage is now visible.
User Manual Model 676 LOKPRINT® | Printer Unpacking / Installation • 11 |