Toshiba IK-TF5C 1P SR 1 Pulse Trigger Sync Reset, Pulse Trigger SYNC-RESET Picture Output Timing

Page 26

( 2 ) 1P SR (1 Pulse Trigger Sync Reset)

Charge begins to accumulate after the trigger input to CC1 of the DIGITAL terminal, the vertical sync signal is reset and frame images are output.

(2. 1) 1 Pulse Trigger SYNC-RESET Picture Output Timing

Negative polarity mode

Trigger*1

Positive polarity mode

About 1 s

Exposure period*2

Exposure completion

0 to 1H*3

(Internal VD)

RGB data (video interval image)

FVAL

LVAL,

DVAL

20H (Partial scanning OFF)

18H (Partial scanning 120fps)

23H (Partial scanning 180fps)

*1: Externally input signal

*2: Exposure time is determined by the setting of "7. 2 (1.3) Changing each setting in E.TRG mode".

*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchro- nized to this and output.

Note:

When the next trigger is input before completion of the output of the video corresponding to the trig- ger, there will be an effect on the video.

26

Image 26
Contents For Customer Use Following information is only for EU-member statesSafety Precautions Avoid setting in humid, smoky, vaporized or dusty places DisclaimerTable of Contents Components Items Controlled by Using on Screen Display Available selectionsNames and Functions Standard Connection Connector Pin AssignmentsConnection Automatic White Balance Manual White Balance Outline OperationWhite Balance Result displayed MeaningShading Correction Shutter speed mode is E.TRG modeGain OFFMode Setting by on Screen Display Using the MenusMenus Changing each setting in Manu modePartial scanning setting Shutter Electronic shutterChanging the shutter speed setting Changing each setting in SS synchro. scan modeMode = SS Changing the polarity of inputting trigger pulse setting Changing each setting in E.TRG modeChanging each setting in 1P SNR mode Changing 1P SNR exposure time settingChanging 1P SR exposure time setting Changing each setting in 1P SR modeMode = E.TRG E.TRG = 1P SR Changing each setting in PW SNR mode Mode = E.TRG E.TRG = PW SNRChanging each setting in PW SR mode Mode = E.TRG E.TRG = PW SRChanging each setting in Gain Changing each setting in RR modeMode = E.TRG E.TRG = RR Changing the gain in Manu modeWHT BAL White balance Changing master pedestal Changing the shading correction modeChanging the manual shading correction setting Changing R pedestalOption Adjusting horizontal phaseSync Data UP, Down Menu UP, DownShutter mode HD input VD input Setting to factory setting statusExternal sync signal polarity External SyncSetting by 1H Setting by the frameUsing the unit with external sync signal Horizontal phase adjustmentEXT Trig External trigger 1P SNR 1 Pulse Trigger Sync Non Reset1 Pulse Trigger SYNC-NON Reset Picture Output Timing Fval Lval DvalInternal VD*3 1P SR 1 Pulse Trigger Sync Reset 1 Pulse Trigger SYNC-RESET Picture Output TimingPW SNR Pulse width trigger SYNC-NON Reset About 7 ∝s PW SR Pulse width trigger SYNC-RESET 1 Pulse Width Trigger SYNC-RESET Picture Output TimingLong Term Exposure RR Reset restartInput Timing Chart Example Partial Scanning OFF All pixels scanning When Partial Scanning Mode is onPartial Read Partial Scanning onInput Output Signal Specificatoins Vertical Output Waveform Timing Chart CCD Output Waveform Timing ChartHorizontal Output Waveform Timing Chart Specifications RGB, 3CCDSymptom Items to be checked External Appearance DiagramBefore Making a Service Call Imaging Systems Division Limited One 1 Year Warranty of Labor and PartsStep-by-step Procedures How to Obtain Warranty Service